Skip to content

What are you looking for?


You may also like

IC200ALG230 GE VersaMax PLC Analog Input ModuleIC200ALG230 GE VersaMax PLC Analog Input ModuleIC200ALG230 GE VersaMax PLC Analog Input Module
IC200ALG230 GE VersaMax PLC Analog Input Module
IC200ALG230 GE VersaMax PLC Analog Input Module
IC200ALG230 GE VersaMax PLC Analog Input Module

IC200ALG230 GE VersaMax PLC Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : IC200ALG230

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The GE IC200ALG230 is a four-channel analog input module engineered for the VersaMax PLC platform. Designed by GE Fanuc, now part of Emerson Automation, it allows accurate and flexible interfacing of analog signals within industrial control systems. The module supports both current and voltage inputs and offers selectable configuration for various process applications, ensuring smooth integration in scalable control environments.

Specifications

  • Model: IC200ALG230

  • Brand: GE

  • Series: VersaMax

  • Type: Analog Input Module

  • Number of Channels: 4 analog input channels

  • Supported Input Signals: 4–20 mA current, ±10 VDC, or 0–10 VDC voltage

  • Input Mode: Selectable between current and voltage via jumpers

  • Voltage Type: Bipolar (default) or unipolar

  • Resolution: 12-bit precision

  • Input Configuration: Single-ended

  • Response Characteristics: Filter response time 5.0 ms, update rate 0.4 ms

  • Backplane Power Consumption: 125 mA at 5 VDC

  • Diagnostic Function: Detects internal power loss

  • LED Indicators:

    • INT PWR for internal power status

    • OK for backplane power indication

  • Error Handling: Configurable to hold the last state or revert to a predefined value

  • Isolation Protection: 250 VAC continuous, 1500 VAC for one minute

  • Compatible Terminals: IC200TBM001, IC200TBM002, IC200TBM005

  • I/O Carrier Compatibility: IC200CHS series

  • Weight: 0.14 kg

Features

  • Flexible Input Configuration: Jumper-selectable between current and voltage inputs to support diverse analog sensors.

  • High Accuracy: 12-bit resolution ensures precise measurement and reliable signal conversion.

  • Fast Response: 0.4 ms update rate supports high-speed process monitoring and control loops.

  • Robust Isolation: Optical isolation between channels and backplane enhances system protection.

  • Status Indication: Dual LED display for internal and backplane power conditions.

  • Error Management: Built-in diagnostics with configurable output response on fault detection.

  • Easy Integration: Designed to work seamlessly with VersaMax I/O carriers and terminal modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more