Skip to content

What are you looking for?


You may also like

1MRK000614-ABr04 ABB Binary Output Module1MRK000614-ABr04 ABB Binary Output Module1MRK000614-ABr04 ABB Binary Output Module
1MRK000614-ABr04 ABB Binary Output Module
1MRK000614-ABr04 ABB Binary Output Module
1MRK000614-ABr04 ABB Binary Output Module

1MRK000614-ABr04 ABB Binary Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1MRK000614-ABr04

PRODUCT TYPE : Binary Output Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 1MRK000614-ABr04, also cataloged as the 1MRK000614-AB Binary Output Module, operates as a dedicated hardware component for on/off control signal execution within ABB Relion protection and control platforms.

Hardware Specifications

Parameter Specification
Model 1MRK000614-ABr04
Brand ABB
Origin Standard ABB Manufacturing
Weight 0.3 kg
Dimensions Standard Relion Chassis Slot
Operating Temp -25 to +70 deg C
Power Consumption 24 VDC Auxiliary Supply Driven
Auxiliary Voltage 24 VDC
Output Contact Count 24 Output Relays
Communication Protocol IEC 61850-8-1 Ed 1 or Ed 2 (Station Bus)
Output Functionality Binary Discrete On/Off Switching

Deterministic Networks & Backplane Communication Velocity

The module executes discrete relay switching outputs to drive external equipment such as circuit breakers, switches, and local status indicators. Station bus integration via IEC 61850-8-1 Ed 1/Ed 2 protocols relies on high-speed backplane bus communication velocity to route GOOSE trip commands and status updates without processing delays. Internal control logic maintains firmware flash compatibility across backplane bus slots to support synchronized time-stamping and deterministic execution.

Frequently Asked Questions

Q: What communication protocol is supported on the station bus for the 1MRK000614-ABr04 module?

A: The module supports IEC 61850-8-1 Edition 1 or Edition 2 protocol standards for station bus integration.

Q: What is the operating temperature range for the 1MRK000614-ABr04 hardware assembly?

A: The module operates within an ambient industrial temperature range of -25 to +70 deg C.

Field Installation Guidelines

  • Verify that the host protection relay frame is fully powered down before inserting or removing the card from the backplane.
  • Wear an ESD-grounded wrist strap during handling to shield internal relay driver circuitry from electrostatic damage.
  • Ensure auxiliary 24 VDC power supply cabling is properly rated and routed separately from high-voltage AC current transformer lines.
  • Secure top and bottom faceplate retention screws firmly to guarantee solid grounding to the main chassis frame.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more