Skip to content

What are you looking for?


You may also like

Honeywell | TC-IDD321 | Experion LS 32-Point Digital Input ModuleHoneywell | TC-IDD321 | Experion LS 32-Point Digital Input ModuleHoneywell | TC-IDD321 | Experion LS 32-Point Digital Input Module
Honeywell | TC-IDD321 | Experion LS 32-Point Digital Input Module
Honeywell | TC-IDD321 | Experion LS 32-Point Digital Input Module
Honeywell | TC-IDD321 | Experion LS 32-Point Digital Input Module

Honeywell | TC-IDD321 | Experion LS 32-Point Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : TC-IDD321

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The TC-IDD321 is a 32-channel Digital Input Module engineered for Honeywell Experion LS and compatible control platforms. Its high-density design captures discrete DC signals from field devices, offering reliable monitoring for sensors, pushbuttons, limit switches, and other industrial inputs. The rugged construction ensures durability in harsh industrial environments while maintaining ease of installation and maintenance.

Specifications

  • Model & Part Number: TC-IDD321

  • Product Type: Digital Input I/O Module

  • Number of Inputs: 32 (organized as 2 groups of 16 points)

  • Input Voltage Range: 10–31.2 VDC at 60°C

  • Nominal Input Voltage: 24 VDC

  • On-State Current (Minimum): 2 mA

  • Off-State Voltage (Maximum): 5 V

  • Off-State Current (Maximum): 1.5 mA

  • Isolation Voltage:

    • Channel-to-channel: 1500 VDC, tested 1 second

    • User-to-system: 1500 VDC, tested 1 second

  • Input Delay Time:

    • Off-to-on: Hardware delay, programmable filter 1 ms or 2 ms

    • On-to-off: Hardware delay, programmable filter 0 ms, 1 ms, 2 ms, 9 ms, or 18 ms

  • Power Dissipation: 6.1 W maximum

  • Short/Inrush Current: 250 mA peak (decays to <37% in 22 ms, without activation)

  • Input Compatibility: IEC Type 1+

  • Backplane Current: See module power consumption data

  • Connection Terminal Block: TC-TBCH, 36-position terminal block

  • Operating Environment: Designed for industrial environments with temperature and vibration tolerance

Features

  • High-Density Input: 32 channels allow compact I/O integration

  • Rugged Design: Engineered for harsh industrial conditions

  • Easy Installation: Standard terminal blocks for quick wiring

  • Wide PLC Compatibility: Works with Experion LS, Allen-Bradley, Siemens, Rockwell, and other PLCs

  • Reliable Isolation: Safe operation with channel-to-channel and system isolation

  • Programmable Filters: Customizable input delay to reduce signal noise

Applications
Ideal for distributed control systems, factory automation, process control, and monitoring discrete field devices. Compatible with legacy and modern PLC environments.

FAQ

Q: How many input channels does TC-IDD321 provide?
A: 32 discrete channels organized into 2 isolated groups.

Q: What voltage range is supported?
A: 10–31.2 VDC with a nominal 24 VDC operation.

Q: Is this module compatible with other PLC systems?
A: Yes, it works with Experion LS, Allen-Bradley, Siemens, Rockwell, and other major PLCs.

Q: Does it include galvanic isolation?
A: Yes, channel-to-channel and user-to-system isolation is tested at 1500 VDC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more