Product Description

The Honeywell 10106/2/1 Digital Input Module is a fail-safe, line-monitored unit designed for use in emergency shutdown (ESD), fire and gas detection (F&G), and interlock systems. It provides secure acquisition of digital signals from field devices such as switches, relays, and alarms, transmitting them reliably to the control system. With fast response times, strong isolation, and diagnostic LED indicators, this module is engineered for dependable operation in demanding industrial environments.

Key Features

  • Model Number: 10106/2/1

  • Type: Digital Input Module (fail-safe, line-monitored)

  • Channels: 16 independent digital inputs

  • Input Type: Dry contact or 24 VDC signals

  • Response Time: < 10 ms

  • Isolation Voltage: > 1500 V AC channel-to-channel

  • LED Indicators: Power, input status, fault diagnostics

  • Operating Temperature: –20 °C to +60 °C

  • Storage Temperature: –40 °C to +85 °C

  • Humidity Range: 5–95% RH, non-condensing

  • Power Supply: 24 VDC ±10%, ~5 W consumption

  • Mounting: DIN rail or rack installation

  • Dimensions: 25 × 140 × 191 mm

  • Weight: 0.2 kg

Application Scenarios

  • Emergency Shutdown Systems: Reliable signal acquisition for critical safety functions

  • Fire & Gas Detection: Integration of alarms and sensors for hazard monitoring

  • Interlock Systems: Ensures secure digital input handling in process safety applications

  • Industrial Automation: Suitable for petrochemical, energy, and manufacturing environments

FAQ

Q: How many input channels does the 10106/2/1 provide?  

A: It supports 16 independent digital input channels.

Q: What is the typical response time?  

A: Less than 10 milliseconds.

Q: What type of signals can be connected?  

A: Dry contact inputs or 24 VDC signals.

Q: How does it compare to the Honeywell 10101/2/1 module?  

A: The 10106/2/1 is optimized for ESD and F&G systems with line monitoring and diagnostic LEDs, while the 10101/2/1 focuses on standard fail-safe digital input handling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more