Skip to content

What are you looking for?


You may also like

Honeywell FC-TSRO-0824 CC V1.1 Digital Output ModuleHoneywell FC-TSRO-0824 CC V1.1 Digital Output ModuleHoneywell FC-TSRO-0824 CC V1.1 Digital Output Module
Honeywell FC-TSRO-0824 CC V1.1 Digital Output Module
Honeywell FC-TSRO-0824 CC V1.1 Digital Output Module
Honeywell FC-TSRO-0824 CC V1.1 Digital Output Module

Honeywell FC-TSRO-0824 CC V1.1 Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : FC-TSRO-0824 CC V1.1

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell FC-TSRO-0824 CC V1.1, also cataloged as the FC-TSRO-0824 Digital Output Field Termination Assembly, operates as a dedicated hardware component for 24 VDC digital discrete signal switching and relay interface execution within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FC-TSRO-0824 CC V1.1
Brand Honeywell
Origin USA
Weight 0.35 kg
Dimensions 15 cm x 8 cm x 3.5 cm
Operating Temp -20 to +70 deg C
Power Consumption 24 VDC field loop powered
Module Type Digital Output Field Termination Assembly
Channels 8 relay / digital output channels
Nominal Voltage 24 VDC

Channel-to-Channel Isolation & Output Loop Execution

The FC-TSRO-0824 CC V1.1 executes discrete switching signals via isolated physical output channels to drive solenoids, relays, and field actuators. Featuring galvanic channel-to-channel isolation between internal backplane control logic and field-side wiring, the module prevents transient inductive kickbacks from disrupting adjacent digital logic or 4-20 mA HART loop protocol instruments. Integrated suppression networks stabilize line switching response during high-duty output toggling.

Frequently Asked Questions

Q: What power source is required to drive output loads connected to the FC-TSRO-0824 CC V1.1?

A: Field output channels require an external regulated 24 VDC power feed connected directly through the field termination assembly screw terminals.

Q: How does the module handle inductive switching noise from external relays and field valves?

A: Internal galvanic channel-to-channel isolation stages decouple backplane logic circuits from field-side voltage spikes and switching transients.

Field Installation Guidelines

  1. Disconnect all 24 VDC field power sources before attaching or removing terminal connections on the FC-TSRO-0824 CC V1.1 module.
  2. Route discrete output conductors in dedicated cable trays separated from high-voltage AC lines to minimize electromagnetic cross-talk.
  3. Ensure terminal block retention screws are torqued properly to maintain steady electrical contact and vibration resistance.
  4. Verify cabinet ambient environmental conditions stay within -20 to +70 deg C to ensure uninterrupted switching performance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more