Product Description

The Honeywell FC‑TSDO‑0824 TSDO‑0824 is a Safe Digital Output Field Termination Assembly (FTA) designed to provide secure and reliable digital output connections in Honeywell safety and process control systems. With eight channels, robust electrical ratings, and compliance with IEC standards, it ensures dependable performance in demanding industrial environments.

Technical Specifications

  • Model / Product No.: FC‑TSDO‑0824 TSDO‑0824

  • Manufacturer: Honeywell

  • Type: Safe Digital Output FTA

  • Number of Channels: 8

  • Maximum Voltage: 36 VDC (IEC 1010:1990, Overvoltage Category 3)

  • Continuous Current per Channel: 1.5 A (actual maximum defined by connected output module)

  • DIN EN Rail Compatibility: TS32 / TS35 × 7.5

  • Rail Length Required: 61 mm (2.40 in)

  • Screw Terminal Specifications:

    • Maximum wire diameter: 2.5 mm² (AWG 14)

    • Strip length: 7 mm (0.28 in)

    • Tightening torque: 0.5 Nm (0.37 ft‑lb)

  • Dimensions (D × W × H): 60 mm × 70 mm × 58 mm

  • Shipping Weight: ~3 kg

  • Warranty: 12 months standard coverage

Key Features

  • Safety‑Certified Output Assembly: Designed for SIL‑rated safety systems

  • Compact DIN Rail Mounting: Fits standard TS32 and TS35 rails with minimal space requirements

  • Reliable Electrical Performance: Supports up to 1.5 A continuous current per channel

  • Industrial Durability: Built for long‑term use in harsh automation environments

  • Ease of Wiring: Screw terminals with defined torque and strip length for secure connections

Application Scenarios

  • Distributed control systems requiring safe digital outputs

  • Emergency shutdown systems (ESD) in oil & gas and petrochemical industries

  • Power generation and heavy manufacturing environments

  • Safety instrumented systems requiring IEC‑compliant output assemblies

FAQ

Q: How many channels does the FC‑TSDO‑0824 provide?  A: It offers 8 independent digital output channels.

Q: What is the maximum current supported per channel?  A: Each channel supports up to 1.5 A continuous current, with the actual maximum defined by the connected output module.

Q: Is this module compatible with standard DIN rails?  A: Yes, it supports TS32 and TS35 × 7.5 DIN rails.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more