Overview

The Honeywell CC-PAOX01 is a high-level HART analog output (AO) module optimized for Honeywell Experion PKS Distributed Control Systems (DCS). It delivers precise, stable 4–20 mA signals across 16 channels, ensuring reliable integration with actuators, recorders, and multivariable instruments in industrial applications.

IOTA Model Variants

  • Non-Redundant: CC-TAOX01 (6")

  • Redundant: CC-TAOX11 (12"), CC-GAOX11 (12")

  • Non-Redundant: CC-GAOX21 (6")

Technical Specifications

  • Manufacturer: Honeywell

  • Model Number: CC-PAOX01

  • Product Type: High-Level HART Analog Output Module

  • Number of Channels: 16

  • Output Signal Type: 4–20 mA

  • Output Ripple: <100 mV peak-to-peak (across 250 Ω load)

  • Temperature Drift: 0.005% of full scale per °C

  • Output Readback Accuracy: ±4% of full scale

  • Current Linearity: ±0.05% of full scale nominal

  • Resolution: ±0.05% of full scale

  • Calibrated Accuracy: ±0.35% of full scale at 25°C, including linearity

  • Directly Settable Output Range: 0 mA, 2.9–21.1 mA

  • Maximum Resistive Load: 800 Ω (24 V supply = 22–28 VDC)

  • Maximum Compliant Voltage: 16 V (24 V supply = 22–28 VDC)

  • Maximum Open-Circuit Voltage: 22 V

Key Features

  • HART Communication Support: Compatible with multivariable transmitters for advanced diagnostics.

  • High Accuracy & Linearity: Maintains precise output with minimal deviation.

  • Multi-Channel Configuration: 16 fully isolated output channels for flexible deployment.

  • Robust Industrial Design: Suitable for harsh environments with high reliability.

  • Configurable Output Range: Supports direct range adjustments and safe-state behaviors.

Applications

  • Driving actuators and recording instruments in process plants

  • Integration with Honeywell Experion PKS DCS

  • High-integrity analog signal control in chemical, refining, and utility sectors

  • Multivariable HART-enabled process instrumentation

FAQ

Q: How many channels does the CC-PAOX01 support?
A: The module supports 16 independent output channels.

Q: Is it HART-compatible?
A: Yes, it fully supports HART-enabled devices for process monitoring and diagnostics.

Q: Can it operate under varying temperatures?
A: Yes, it maintains performance with a temperature drift of 0.005%/°C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more