Overview

The HIMA F3300/F 3300 is an 8-channel output module engineered for safety-related applications. It supports resistive and inductive loads up to 500 mA per channel and lamp loads up to 4 W. Designed for secure operation, the module integrates safe isolation and automatic functional testing to ensure reliable output signals under all operating conditions.

Technical Specifications

  • Manufacturer: HIMA

  • Model Number: F3300/F 3300

  • Product Type: 8-Fold Digital Output Module

  • Output Channels: 8

  • Output Current: 500 mA per channel, short-circuit protected

  • Internal Voltage Drop: Max 2 V at 500 mA load

  • Maximum Line Resistance: 11 Ω (input + output)

  • Undervoltage Tripping Threshold: ≤ 16 V

  • Short Circuit Current Operating Point: 0.75–1.5 A

  • Output Leakage Current: Max 350 μA

  • Test Signal Duration: Max 200 μs

  • Space Requirement: 4 TE

  • Operating Power: 5 V DC (110 mA), 24 V DC (180 mA additional load)

  • Cable Type: LiYY 8 × 0.5 mm² or 16 × 0.5 mm²

  • Recommended Diode: 1N4007 or 1N4448

Key Features

  • Eight independent channels for comprehensive control capabilities

  • Integrated safe isolation and automated output testing during operation

  • Ensures no output signal in case of L- supply break

  • Short-circuit proof and high reliability for industrial environments

  • Compact 4 TE footprint for efficient panel integration

Application Scenarios

The HIMA F 3300 is suitable for:

  • Safety-related process control and monitoring applications

  • Switching of resistive, inductive, and lamp loads

  • Integration into HIMatrix safety controller systems

  • Industrial setups where secure, reliable output channels are critical

FAQ

Q: How many output channels does F3300 provide?
A: The module provides 8 independent output channels.

Q: What types of loads are supported?
A: It supports resistive and inductive loads up to 500 mA and lamp connections up to 4 W.

Q: What safety features does it include?
A: Safe galvanic isolation, automatic functional testing, short-circuit protection, and L- supply break detection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more