Overview

The Honeywell CC-PAONO1 is a high-level analog output (AO) module engineered for precise control in process automation systems. Designed for integration with Honeywell distributed control systems, it delivers accurate 4–20 mA output signals and supports both non-redundant and redundant IOTA configurations. Its robust architecture ensures reliable performance for critical industrial applications.

Key Features

  • Provides 16 analog output channels with configurable ranges

  • Supports high-accuracy output with ±0.35% full-scale calibrated precision at 25°C

  • Low output ripple (<100 mV peak-to-peak) ensures stable signals

  • Redundant IOTA option allows seamless switchover within ≤10 ms

  • High-resolution output (±0.05% of full scale) and excellent linearity

  • Response time under 80 ms for fast control loop performance

  • Supports resistive loads up to 800 Ω with 24 VDC supply

Technical Specifications

  • Model Number: CC-PAONO1

  • Product Type: Analog Output (AO) Module – High-Level

  • IOTA Variants: Non-Redundant (CC-TAON01, 6"), Redundant (CC-TAON11, 12")

  • Output Type: 4–20 mA

  • Output Channels: 16

  • Output Ripple: <100 mV peak-to-peak at 250 Ω load

  • Output Temperature Drift: 0.005% of full scale per °C

  • Output Readback Accuracy: ±4% of full scale

  • Output Current Linearity: ±0.05% of full scale nominal

  • Resolution: ±0.05% of full scale

  • Calibrated Accuracy: ±0.35% of full scale at 25°C

  • Settable Output Range: 0–21.1 mA

  • Maximum Resistive Load: 800 Ω (with 24 V supply at 22–28 VDC)

  • Maximum Output Compliant Voltage: 16 V

  • Maximum Open Circuit Voltage: 22 V

  • Response Time: <80 ms to settle within 1% of final value

  • Switchover Gap (Redundant Mode): ≤10 ms for 0 mA output

Application Scenarios

The CC-PAONO1 is ideal for:

  • High-precision control loops in process automation

  • Critical applications requiring redundant analog output for reliability

  • Integration with Honeywell C300 or Experion control systems

  • Industries like oil & gas, chemical processing, and power generation

FAQ

Q: How many output channels does the CC-PAONO1 provide?
A: The module offers 16 analog output channels.

Q: What is the switchover time for the redundant IOTA version?
A: The redundant module switches over in ≤10 ms.

Q: What is the output range?
A: The module supports 0 mA to 21.1 mA, configurable for application needs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more