Skip to content

What are you looking for?


You may also like

HC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input ModuleHC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input ModuleHC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input Module
HC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input Module
HC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input Module
HC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input Module

HC900 Controller 900A01-0001 | Honeywell | 8-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 900A01-0001

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The 900A01-0001 from Honeywell is an 8-channel universal analog input module designed for the HC900 Controller. It supports multiple signal types and provides integrated galvanic isolation, delivering precise and reliable data acquisition for industrial process control.

Technical Specifications

  • Model Number: 900A01-0001

  • Inputs: 8 isolated analog channels

  • Supported Input Types:

    • Thermocouple: B, E, J, K, T, R, S, N

    • RTD: 100/500/1000 Pt, Cu10

    • mV: 0–100 mV

    • Voltage: 0–10 V

    • Current: 4–20 mA

    • Slidewire: 100–6500 Ω

  • Input Impedance:

    • Thermocouple/mV: 10 MΩ

    • Voltage: 1 MΩ

    • Current: 250 Ω

  • Galvanic Isolation:

    • 400 VDC channel-to-channel

    • 1 kVDC field-to-logic

  • Noise Rejection: 60 dB series mode, 130 dB common mode at 120 VAC

  • Accuracy: ±0.1% of range (factory), ±0.05% after field calibration

  • Cold Junction Accuracy: ±0.7°C

  • Temperature Effect: ±0.01% full scale per °C

  • A/D Resolution: 15 bits

  • Update Rate: 500 ms

  • Power Supply Loading: 5 V @ 40 mA max, 24 V @ 25 mA max

  • Burnout Detection: Configurable upscale/downscale or defined value for T/C, mV, V; inherent upscale for RTD, downscale for mA

  • Over-range Limits: ±10% linear ranges, ±1% non-linear ranges

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 70°C

  • Relative Humidity: 10–90% (operating), 5–95% (storage)

  • Terminal Block: 20-pin Euro or Barrier style, tin/gold-plated contacts

  • Dimensions (H × W × D): 137 × 35.6 × 66 mm

  • Weight: 210 g

Key Features

  • Supports diverse analog signals including thermocouples, RTDs, mV, voltage, current, and slidewires

  • Integrated point-to-point and backplane isolation ensures reliable measurements

  • Synchronous analog-to-digital conversion with high accuracy

  • LED indicators for channel and module diagnostics

  • Configurable burnout and over-range detection for robust safety

Applications
Designed for use in Honeywell HC900 controllers, suitable for process monitoring, industrial automation, and systems requiring accurate multi-channel analog inputs.

FAQ
Q: How many channels does 900A01-0001 support?
A: 8 isolated analog input channels.

Q: Which signal types are supported?
A: Thermocouple, RTD, mV, voltage, current, and slidewire inputs.

Q: Does it provide galvanic isolation?
A: Yes, 400 VDC between channels and 1 kVDC from field to logic.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more