Skip to content

What are you looking for?


You may also like

General Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination ModuleGeneral Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination ModuleGeneral Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination Module
General Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination Module
General Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination Module
General Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination Module

General Electric DS200TBCBG1AAA 4-20 mA RTD Input Termination Module


Only 10 left - Selling fast

PRODUCT SKU : DS200TBCBG1AAA

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for signal interface within Mark V Speedtronic systems, the GE DS200TBCBG1AAA (DS200TBCB Input Termination Module) provides direct physical execution for RTD and current loop sensor landing.

Hardware Specifications

Parameter Specification
Model DS200TBCBG1AAA
Brand General Electric
Origin USA
Power Consumption +5 V DC, 6 A
Core Function RTD and 4-20 mA signal termination

Industrial Control & Firmware Compatibility

The DS200TBCBG1AAA operates as a passive interface board, facilitating I/O density scaling by routing temperature and process current signals to the TCCB board within the core. Deterministic signal transmission is achieved through a fixed hardware architecture; the module does not require firmware, thereby avoiding firmware flash compatibility requirements. Eight of the input channels support hardware-level reconfiguration via jumpers to switch from 4-20 mA to 0-1 mA signal ranges. Signal integrity is maintained through integrated termination logic that interfaces directly with the backplane bus, ensuring that converted sensor data is correctly mapped to the system's control processors.

Frequently Asked Questions

Q: Can the input range be modified for specific channels?

A: Yes. Eight of the 4-20 mA input channels feature hardware jumpers that allow for reconfiguration to support 0-1 mA input signals. This physical adjustment must be made at the board level.

Q: Is this module hot-swappable during system operation?

A: No. The TBCB module must be de-energized before removal or installation. Ensure that all power is removed from the associated core and terminal blocks to prevent damage to the module circuitry or accidental disruption of the control loops.

Field Installation Guidelines

  • Signal Routing: Ensure all RTD and mA sensor leads are landed securely on the terminal blocks. Verify signal polarity for 4-20 mA loops to prevent open-circuit or reversed-polarity conditions.
  • Jumper Configuration: If using the 0-1 mA input range, verify that the corresponding jumpers are correctly set before energizing the module. Improper jumper settings may lead to signal reading errors at the controller level.
  • Grounding and Shielding: Terminate sensor cable shields at the designated chassis ground points. Maintaining a low-impedance ground reference is necessary to minimize common-mode noise on the sensitive RTD temperature measurement circuits.
  • Cabinet Integration: Mount the module in location seven of the core assembly. Ensure proper alignment with the backplane connector to avoid pin deformation during insertion.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more