Product Description

The IC694MDL940 relay output module from GE Fanuc PACSystems RX3i series is designed to provide flexible AC/DC switching capabilities for industrial automation systems. With individually isolated outputs, robust isolation ratings, and long relay contact life, this module ensures reliable performance in demanding control environments.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL940

  • Product Type: Relay Output Module

  • Condition: New / Never Used Surplus

  • Number of Channels: 8 relay outputs

  • I/O Capacity: 16 individually isolated Normally Open (Form A) contacts

  • Groups: 4 groups of 4 outputs each

  • Operating Voltage: 5–30 VDC or 5–250 VAC (50/60 Hz)

  • Rated Voltage: 24 VDC; 120/240 VAC

  • Switching Current: 2 A maximum per output point

  • Maximum Load: 2 A pilot duty per output; 4 A maximum per common

  • Inrush Current Rating: 5 A

  • Response Time: ≤ 15 ms

  • Minimum Load: 10 mA

  • Isolation: 250 VAC continuous; 1500 VAC withstand for 1 minute (field to backplane and frame ground)

  • Point-to-Point Isolation: Yes

  • Relay Contact Life: 100,000–1,000,000 operations depending on voltage and load type

  • Backplane Current Draw: 7 mA from 5 V bus (all outputs ON); 135 mA from 24 V relay bus (all outputs ON)

  • LED Indicators: 32 individually numbered LEDs for status monitoring

  • Location: PACSystems RX3i PLC I/O slots

  • Weight: 0.37 kg

Application Scenarios

  • Industrial control systems requiring AC/DC relay switching

  • Applications needing isolated outputs for safety and reliability

  • Environments where long relay contact life and diagnostic LEDs are essential

FAQ

Q: How many outputs are available on this module?  A: 8 relay channels, with 16 isolated Normally Open contacts.

Q: What voltage ranges are supported?  A: 5–30 VDC and 5–250 VAC at 50/60 Hz.

Q: What is the maximum load per output?  A: 2 Amps pilot duty per output, with 4 Amps maximum per common.

Q: Does the module provide isolation?  A: Yes, 250 VAC continuous isolation and 1500 VAC withstand for 1 minute.

Q: What is the expected relay contact life?  A: Between 100,000 and 1,000,000 operations depending on voltage and load type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more