Skip to content

What are you looking for?


You may also like

GE PACSystems RX3i IC694MDL916 16-Point Relay Output ModuleGE PACSystems RX3i IC694MDL916 16-Point Relay Output ModuleGE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module
GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module

GE PACSystems RX3i IC694MDL916 16-Point Relay Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC694MDL916

PRODUCT TYPE : Relay Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL916 relay output module from GE Fanuc PACSystems RX3i series provides sixteen individually isolated Form A (Normally Open) relay outputs. Designed for flexible AC/DC switching, it supports a wide voltage range and robust isolation, making it suitable for industrial automation systems requiring reliable relay-based control.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL916

  • Product Type: Relay Output Module

  • Number of Channels: 16 isolated relay outputs

  • Contact Form: Form A (Normally Open)

  • Operating Voltage Range: 0–125 VDC / 5–250 VAC

  • Nominal Output Voltage: 5/24/125 VDC; 120–240 VAC

  • Output Current per Channel:

    • Minimum: 10 mA

    • Maximum: 4 A (5–250 VAC resistive/general purpose)

    • Maximum: 4 A (5–30 VDC resistive)

    • Maximum: 200 mA (125 VDC resistive)

    • Pilot duty: 2 A per output (5–30 VDC, 5–250 VAC)

    • Lamp load: 2 A per output (5–30 VDC, 5–250 VAC)

  • Switching Current: 4 A maximum

  • Switching Frequency: 20 cycles per minute maximum

  • Response Time: ≤ 10 ms

  • Relay Contact Life: 200,000–1,000,000 operations depending on load type

  • Isolation (Field to Backplane & Frame Ground): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Isolation (Point-to-Point): Yes

  • Isolation (Group-to-Group): 250 VAC continuous; 1500 VAC withstand for 1 minute

  • Backplane Current Draw: 300 mA at 5 VDC (all outputs ON); 150 mA at 24 VDC relay power (all outputs ON)

  • Terminal Block Options: IC694TBB032 (box-style), IC694TBB132 (extended box-style), IC694TBS032 (spring-style), IC694TBS132 (extended spring-style)

  • Installation: RX3i PACSystems PLC I/O slots

  • Configuration Software: Proficy Machine Edition v5.5 SP2 or later

  • Weight: 0.69 lbs (0.31 kg)

  • Lifecycle Status: Active

Application Scenarios

  • Industrial automation systems requiring AC/DC relay switching

  • Applications needing isolated outputs for safety and reliability

  • Environments where pilot duty and lamp load switching are common

FAQ

Q: How many relay outputs does this module provide?  A: 16 individually isolated Form A (Normally Open) relay outputs.

Q: What voltage ranges are supported?  A: 0–125 VDC and 5–250 VAC.

Q: What is the maximum switching current?  A: 4 Amps for resistive loads at 5–250 VAC or 5–30 VDC.

Q: What is the expected relay contact life?  A: Between 200,000 and 1,000,000 operations depending on voltage and load type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more