GE IS210BPPCH1ACA Mark VIe I/O Pack Processor DaughterboardGE IS210BPPCH1ACA Mark VIe I/O Pack Processor DaughterboardGE IS210BPPCH1ACA Mark VIe I/O Pack Processor Daughterboard
GE IS210BPPCH1ACA Mark VIe I/O Pack Processor Daughterboard
GE IS210BPPCH1ACA Mark VIe I/O Pack Processor Daughterboard
GE IS210BPPCH1ACA Mark VIe I/O Pack Processor Daughterboard

GE IS210BPPCH1ACA Mark VIe I/O Pack Processor Daughterboard


Only 10 left - Selling fast

PRODUCT SKU : IS210BPPCH1ACA

PRODUCT TYPE : Processor Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS210BPPCH1ACA, also cataloged as the IS210BPPC Processor Daughterboard, operates as a dedicated hardware component for localized I/O signal processing and safety instrumented functions within GE Mark VIe control platforms.

Hardware Specifications

Parameter Specification
Model IS210BPPCH1ACA
Brand General Electric
Origin USA
Weight 0.25 kg
Dimensions 120 x 85 x 25 mm
Operating Temp -30 to 65 deg C
Power Consumption 5 W
Functional Acronym BPPC
System Series Mark VIe (not compatible with Mark VIeS)
Board Assembly Type IS210 Special Modular Assembly
Component Technology Surface Mount Technology (SMT) on both board sides
Board Protection Conformal Coating
Terminal Board Compatibility Dual and Triple Modular Redundant (TMR) terminal boards
Revision Matrix ACA (2 Functional revisions, 1 Artwork configuration revision)
Onboard Components ICs, Transistors, Resistors, Capacitors, Chokes, Diodes, Fuse, Jumpers, TP Test Points
Interface Ports 2 x Board-edge communication ports

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The IS210BPPCH1ACA interfaces directly with terminal boards to maintain high-speed signal processing and control loop execution. Onboard integrated circuits manage real-time data serialization, preserving backplane bus communication velocity across dual and TMR hardware architectures. The board supports auto-reconfiguration during module replacement, maintaining firmware flash compatibility when swapping legacy BPPB hardware for BPPC packs. ToolboxST software branding routines enable functional safety code validation, allowing compliant operation within IEC 61511 Safety Instrumented Function (SIF) applications.

Frequently Asked Questions

Q: Is the IS210BPPCH1ACA backward compatible with older BPPB processor components?

A: Yes, the BPPC module can be mixed with older BPPB components on dual or TMR terminal boards, supporting automatic reconfiguration upon replacement.

Q: Can the IS210BPPCH1ACA processor board be installed in a Mark VIeS safety system?

A: No, Mark VIeS systems require specific PBBC processor packs ending in S1B; the IS210BPPCH1ACA is explicitly non-compatible with Mark VIeS racks.

Q: How is safety code verification managed on the BPPC board?

A: The board supports software branding executed within the ToolboxST application, which marks certified application code for IEC 61511 compliant safety instrumented functions.

Field Installation Guidelines

Ensure all system power sources feeding the terminal board assembly are completely de-energized prior to removing or installing the daughterboard. Wear a verified grounded ESD wrist strap throughout handling to protect dual-sided surface-mount technology (SMT) components from static discharge. Align the daughterboard with the mounting standoffs, press evenly to engage the edge ports, and secure using metallic screws through the conductive-ringed factory mounting holes to establish a clean grounding circuit. Verify jumper configurations match system requirements before re-applying power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more