Skip to content

What are you looking for?


You may also like

GE IS210AEBIH1BED Mark VIe Digital Input Expansion ModuleGE IS210AEBIH1BED Mark VIe Digital Input Expansion ModuleGE IS210AEBIH1BED Mark VIe Digital Input Expansion Module
GE IS210AEBIH1BED Mark VIe Digital Input Expansion Module
GE IS210AEBIH1BED Mark VIe Digital Input Expansion Module
GE IS210AEBIH1BED Mark VIe Digital Input Expansion Module

GE IS210AEBIH1BED Mark VIe Digital Input Expansion Module


Only 10 left - Selling fast

PRODUCT SKU : IS210AEBIH1BED

PRODUCT TYPE : Digital I/O Cards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete input processing and bridge interface routing in Mark VIe automation architectures, the GE IS210AEBIH1BED (IS210AEBI Digital Input Expansion Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model IS210AEBIH1BED
Brand GE / General Electric
Origin USA
Operating Temp 0 deg C to 60 deg C
Power Consumption Rack Backplane Powered
Product Series Mark VIe / IS210 Series
Function Digital Input Expansion / Bridge Interface Card
Input Channels 32 Isolated Discrete Input Channels
Isolation Voltage 2500 VAC RMS Typical
Field Connectivity Dry Contact Devices (Form A/C)
Backplane Interface AEBI / VMEbus Compatible
Diagnostics Built-in Self-Monitoring
Circuit Protection PCB Conformal Coating

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The IS210AEBIH1BED processes 32 isolated discrete channels through dedicated signal conditioning circuits prior to transferring state vectors across the AEBI backplane interface. Internal logic synchronization protects data transfers against bus contention, maintaining deterministic timing and high backplane bus communication velocity across adjacent card slots. Onboard flash memory structures validate firmware flash compatibility during rack boot cycles, automatically matching module configuration parameters with the main controller.

Frequently Asked Questions

Q: What isolation rating is provided between the 32 input channels and the backplane logic?

A: The board provides galvanically isolated channel routing rated up to approximately 2500 VAC RMS to prevent transient voltage spikes from reaching backplane circuits.

Q: What type of field contacts are compatible with the IS210AEBIH1BED input terminals?

A: The module is designed to interface directly with dry contact field devices configured in either Form A or Form C contact topologies.

Q: How does the module verify onboard hardware integrity during operation?

A: Integrated self-monitoring diagnostic routines continuously check internal power rails, channel state consistency, and backplane communication integrity.

Field Installation Guidelines

  1. De-energize all primary cabinet power supplies and field contact sensing loops before inserting or removing the module.
  2. Connect an ESD grounding wrist strap to an unpainted ground point on the rack frame prior to handling the circuit board.
  3. Align the card edges with the designated rack guides and slide the module inward until the rear pins lock into the keyed backplane connector.
  4. Tighten the top and bottom retention screws to secure the module and maintain frame ground continuity.
  5. Verify that all field wiring shields connect to the cabinet single-point ground bar to minimize EMI interference on discrete lines.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more