Product Description

The IC200MDL741 is a 16-point discrete output module from GE Fanuc’s VersaMax series, providing reliable DC load control for industrial automation systems. Designed for seamless integration with VersaMax PLCs, this module features robust fault protection and comprehensive status indicators to ensure operational safety and monitoring.

Technical Specifications

  • Manufacturer: GE Fanuc

  • Model / Part Number: IC200MDL741

  • Module Type: Discrete Output Module

  • Series: VersaMax

  • Number of Outputs: 16 points (single group)

  • Logic Type: Positive Logic / Sourcing

  • Nominal Output Voltage: 24 VDC

  • Operational Voltage Range: 18–30 VDC

  • Point-to-Point Isolation: None

  • Group-to-Group Isolation: None

  • Load Protection: Short-circuit protection, overcurrent monitoring, free-wheeling diodes

  • External Power Supply Requirement: 18–30 VDC nominal

  • Backplane Current Consumption: 75 mA at 5 VDC

  • LED Indicators: One per output point plus "OK" and "FLD PWR" LEDs

  • Weight: 0.25 lbs (0.11 kg)

Features

  • 16-point sourcing outputs for precise DC load control

  • Integrated fault protection for overloads and short circuits

  • Individual LED status for each output and power indicators

  • Compact design for easy VersaMax panel installation

  • No isolation between points simplifies system wiring

Applications

  • Driving DC actuators, solenoids, and relay loads

  • Expansion module for VersaMax PLCs in distributed I/O systems

  • Industrial control panels requiring fault-monitored DC outputs

FAQ / Comparison

  • Q: How does IC200MDL741 compare to IC200MDL740?
    A: Both modules provide 16 points, but IC200MDL741 includes free-wheeling diode protection, whereas IC200MDL740 focuses on sourcing output with different current characteristics.

  • Q: Is external power mandatory for operation?
    A: Yes, external DC power is required to supply the output load safely.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more