Skip to content

What are you looking for?


You may also like

GE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input ModuleGE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input ModuleGE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input Module
GE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input Module
GE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input Module
GE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input Module

GE Fanuc VersaMax IC200ALG630 | 7-Channel 16-Bit Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : IC200ALG630

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200ALG630 Analog Input Module is engineered for precise thermocouple and millivolt signal measurement. With seven input channels, high resolution, and advanced diagnostics, it provides reliable performance for temperature monitoring and low-level voltage applications in industrial automation systems.

Technical Specifications

  • Model / Part Number IC200ALG630

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Type Analog Input Module

  • Weight 0.38 lbs (0.17 kg)

  • Channels 7 analog input channels

  • Supported Thermocouple Types J, K, T, S, R

  • Supported Millivolt Ranges ±19.5 mV, ±39 mV, ±78.125 mV, ±156.25 mV, ±312.5 mV, ±625 mV

  • Resolution 16-bit (digital resolution: 15 bits plus sign)

  • Update Rate 60–70 ms per channel depending on frequency

  • Accuracy at 25°C ±0.2% for voltage measurement, ±0.15% for thermocouple measurement

  • Temperature Sensitivity (0–60°C) ±0.004% of reading, ±1.5 µV per °C referred to input

  • Frequency 50/60 Hz

  • Operating Temperature Range 0–60°C ambient

  • Backplane Current Consumption 5 V output: 125 mA max; 3.3 V output: 125 mA max

  • Diagnostics Open thermocouple detection, over/under range, high/low alarm, thermistor error

  • Isolation 250 VAC continuous, 1500 VAC for 1 minute (input to logic and frame ground)

  • Status Indicators OK LED

Application Scenarios

  • Multi-channel thermocouple integration for industrial process monitoring

  • Low-level millivolt signal measurement in laboratory or production environments

  • Systems requiring fast update rates and high accuracy for temperature control

FAQ

Q: How many input channels does the IC200ALG630 provide?  A: It offers seven analog input channels.

Q: Which thermocouple types are supported?  A: J, K, T, S, and R thermocouples are supported.

Q: What is the resolution of this module?  A: It provides 16-bit resolution, ensuring precise measurement accuracy.

Q: Does the module include diagnostics?  A: Yes, it includes open thermocouple detection, range alarms, and thermistor error reporting.

Comparison with Similar Models

  • IC200ALG620-JF: 4-channel RTD/resistance input, 16-bit resolution, advanced diagnostics

  • IC200ALG430: 4 analog inputs + 2 analog outputs, 12-bit resolution, mixed functionality

  • IC200ALG630: 7-channel thermocouple/millivolt input, 16-bit resolution, optimized for temperature and voltage measurement

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more