Overview

The GE Fanuc IC695ALG808 is an 8-channel analog output module with full channel-to-channel isolation, designed for PACSystems RX3i. It delivers precise voltage and current outputs, making it ideal for control systems requiring high-resolution analog signaling with electrical isolation between channels.

Technical Specifications

  • Model: IC695ALG808

  • Manufacturer: GE Fanuc

  • Product Type: Isolated Analog Output Module

  • Product Line: RX3i PACSystems

  • Number of Channels: 8 analog output channels

  • Module Slots Occupied: 1 backplane slot

  • Output Ranges – Current: 0–20 mA, 4–20 mA

  • Output Ranges – Voltage: ±10 VDC, 0–10 VDC

  • Resolution:

    • ±10 V: 15.9 bits minimum

    • 0–10 V: 14.9 bits minimum

    • 0–20 mA: 15.9 bits minimum

    • 4–20 mA: 15.6 bits minimum

  • Maximum Output Load:

    • Current: 1350 Ω maximum, 10 μH max inductance

    • Voltage: 2 kΩ minimum, 1 μF max capacitance

  • Internal Power Consumption: 450 mA @ 3.3 V maximum

Application Scenarios

The IC695ALG808 module is commonly used for:

  • Driving actuators or process valves requiring precise current or voltage outputs

  • Systems requiring channel-to-channel isolation to prevent cross-talk

  • Multi-channel analog output applications in distributed PACSystems RX3i architectures

Comparison with Similar Modules

  • IC695ALG808: 8 isolated analog output channels, high-resolution, flexible current and voltage ranges

  • IC695ALG806: 6 isolated analog outputs, slightly smaller module footprint, similar resolution

  • IC695ALG810: 8-channel isolated output with extended voltage/current range for high-power applications

FAQs

Q: Can IC695ALG808 handle both voltage and current outputs?
A: Yes, it supports 0–20 mA, 4–20 mA, ±10 V, and 0–10 V output signals.

Q: Is channel-to-channel isolation included?
A: Yes, all 8 channels are fully isolated to prevent interference.

Q: How many backplane slots does the module occupy?
A: The module occupies one slot on the RX3i backplane.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more