PRODUCT SKU : F60AI801

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The HIMA F60 AI 801 (984600801) is a high-integrity analog input solution designed for the HIMatrix F60 safety-related controller series. Engineered for SIL 3 applications, this module provides the precision and diagnostic coverage required for mission-critical monitoring in hazardous environments. It serves as a robust interface between field sensors and the central safety logic, ensuring fail-safe data transmission via SafeEthernet.

Core Technical Specifications

  • Input Architecture: 8 independent, high-precision analog channels.

  • Signal Support: Fully configurable for 0/4-20 mA current loops or 0-10 V voltage inputs.

  • Data Resolution: 16-bit processing for high-fidelity signal acquisition.

  • Measurement Precision: ±0.1% of full-scale value at 25°C, ensuring minimal signal drift.

  • Connectivity Protocols: Supports SafeEthernet for safety-critical loops and Modbus TCP for integration with standard SCADA/HMI systems.

  • Fault Detection: Comprehensive internal diagnostics for open-circuit detection, short-circuits, and signal out-of-range monitoring.

Operating Parameters

  • Nominal Supply Voltage: 24 VDC (Functional range: 18 V to 30 V).

  • Current Consumption: Approximately 200 mA at 24 V (Maximum power draw: 5 W).

  • Temperature Tolerance: Designed for industrial operating environments from 0°C to +60°C.

  • Isolation: Galvanic isolation between the input channels and the internal system bus.

Application Scenarios

The F60 AI 801 is typically deployed where sensor failure could lead to catastrophic events. Common applications include:

  • Pressure Monitoring: High-pressure trip systems in chemical processing.

  • Level Control: Overfill protection systems for fuel storage tanks.

  • Gas Detection: Integration with safety-rated toxic or flammable gas sensors.

Frequently Asked Questions

Q: Does the F60 AI 801 require specific software for configuration?A: Yes, the module is configured using the HIMA SILworX engineering tool, which allows for individual channel parameterization and safety logic mapping.

Q: Can I use this module for non-safety-related measurements?A: While designed for SIL 3 safety functions, it can certainly process standard industrial signals, providing the added benefit of high-end diagnostic feedback for non-critical processes.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more