Skip to content

What are you looking for?


You may also like

DX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output ModuleDX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output ModuleDX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output Module
DX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output Module
DX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output Module
DX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output Module

DX561 1TNE968902R2301 ABB S500-eCo Digital Input/Output Module


Only 10 left - Selling fast

PRODUCT SKU : DX561 1TNE968902R2301

PRODUCT TYPE : Digital Input/Output Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DX561 1TNE968902R2301, also cataloged as the DX561 Digital Input/Output Modules, operates as a dedicated hardware component for discrete signal processing within ABB S500-eCo automation platforms. The unit processes 8 digital input channels with sink/source capability alongside 8 digital transistor outputs in a 1-wire configuration.

Hardware Specifications

Parameter Specification
Model DX561 (Order Code: 1TNE968902R2301)
Brand ABB
Origin Germany
Weight 0.12 kg
Dimensions 34 mm x 74 mm x 135 mm (W x H x D)
Operating Temp 0 to +60 deg C
Power Consumption Powered via 24 VDC system connection
Digital Inputs 8 DI (24 VDC, configurable sink/source)
Digital Outputs 8 DO (24 VDC, 0.5 A transistor outputs)
Wiring Topology 1-wire connection architecture
Product Type Digital Input/Output Modules

Firmware Flash Compatibility and Deterministic I/O Processing

The DX561 module interfaces with the S500-eCo CPU carrier through high-density lateral bus connectors, maintaining strict firmware flash compatibility across the controller platform. Internal switching stages ensure deterministic I/O scan execution and high backplane bus communication velocity, transferring 16 discrete signal states per cycle without latency or buffer overflows.

Frequently Asked Questions

Q: Does the DX561 support hot-swapping on an active S500-eCo terminal bus?

A: No. System power and 24 VDC field supplies must be disconnected prior to mounting or dismounting the module to prevent backplane bus communication faults or transistor output damage.

Q: How are sinking and sourcing field input contacts configured on the 8 DI channels?

A: The digital input channels support both sinking (NPN) and sourcing (PNP) wiring layouts, configured by changing the common return reference potential on the module's front terminal block.

Field Installation Guidelines

  1. Lock the DX561 module onto a standard 35 mm DIN rail adjacent to the S500-eCo CPU or expansion base.
  2. Slide the module sideways until the lateral backplane bus connector fully seats into the adjacent rack connector.
  3. Terminate 24 VDC field power supply, digital inputs, and 0.5 A transistor load wires according to the 1-wire pinout schematic.
  4. Ensure the DIN rail maintains low-impedance bonding to the main cabinet grounding bar to provide adequate shielding against high-frequency electrical noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more