Skip to content

What are you looking for?


You may also like

ControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16IControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16IControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16I
ControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16I
ControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16I
ControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16I

ControlLogix 16-Point AC Output Module | Allen-Bradley | 1756-OA16I


Only 10 left - Selling fast

PRODUCT SKU : 1756-OA16I

PRODUCT TYPE : Digital AC Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-OA16I is a high-performance ControlLogix digital AC output module featuring 16 individually isolated points. Designed for reliable switching of AC loads in control systems, it provides precise output timing, robust isolation, and efficient power handling suitable for demanding industrial environments.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-OA16I

  • Product Type: Digital AC Output Module

  • Product Line: ControlLogix

  • Number of Outputs: 16 isolated AC outputs

  • Output Voltage: 120/240 VAC

  • Operating Voltage Range: 74–265 VAC

  • OFF-to-ON Delay Time: 9.3 ms @ 60 Hz, 11 ms @ 50 Hz

  • OFF-State Leakage Current: 3 mA per point

  • Continuous Current per Point: 2 A @ 30°C, 1 A @ 60°C (linear derating)

  • Maximum Continuous Module Current: 5 A @ 30°C, 4 A @ 60°C

  • Backplane Current: 225 mA @ 5.1 VDC; 3 mA @ 24 VDC

  • Power Dissipation (Max): 5.5 W @ 60°C

  • Isolation Voltage: 50 V continuous

  • Removable Terminal Blocks: 1756-TBCH, 1756-TBS6H

  • Enclosure: Open-type, no enclosure required

Key Features

  • 16 individually isolated outputs for flexible AC load control

  • Supports both 120 VAC and 240 VAC systems

  • Fast OFF-to-ON switching ensures accurate output timing

  • Linear derating accommodates high-temperature operation

  • Removable terminal blocks simplify wiring and maintenance

Applications

  • AC load control in ControlLogix systems

  • Lighting, motor, and solenoid control

  • Integration with high-voltage discrete control systems

FAQs

Q1: What is the maximum current per output?
Each output supports 2 A at 30°C and 1 A at 60°C, with module max 5 A / 4 A.

Q2: Does the module support isolated outputs?
Yes, all 16 points are individually isolated for safe AC operation.

Q3: Can it be installed without an enclosure?
Yes, the module is open-type and does not require an enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more