Overview

The Allen-Bradley 1797-BIC is a bus isolator module designed for FLEX I/O and FLEX Ex configurations, enabling intermixed systems that combine intrinsically safe (IS) and non-intrinsically safe modules. It allows modules to be mounted on DIN rails while maintaining galvanic isolation, ensuring safe and cost-effective integration across hazardous and safe areas.

This module is ideal for applications where FLEX Ex I/O and communication adapters require separation or when physical space constraints exist in industrial control systems.

Technical Specifications

I/O Module Capacity

  • Supports up to 8 FLEX Ex modules

Indicators

  • Power LED: Green when the module is powered

Isolation

  • Flexbus to Flexbus: Galvanic isolation per DIN EN 60079-11

  • Flexbus Slave Side to Power Supply: Galvanic isolation per DIN EN 60079-11

Power Requirements

  • Supply Voltage: 18–32 V DC @ 0.15 A

  • Maximum Input Voltage (Um): 253 V AC

  • Power Dissipation: 2.1 W

  • Thermal Dissipation: 7.2 BTU/hr

Intrinsic Safety Certification

  • Module Type: [Ex ib] IIC certified

Electrical Connections

  • Maximum Conductor Size: 4 mm² (12 AWG) stranded

  • Maximum Insulation Thickness: 1.2 mm (3/64 in)

Environmental Ratings

  • Operating Temperature: −20 to 70 °C (−4 to 158 °F)

  • Storage Temperature: −40 to 85 °C (−40 to 185 °F)

  • Relative Humidity: 5–95%, non-condensing

  • Shock: 30 g, 11 ms pulse width (operating & non-operating)

  • Vibration: 5 g, 10–500 Hz per IEC 68-2-6

Mechanical Dimensions

  • Size: 94 × 75 × 87 mm

  • Weight: ~200 g

Key Features

  • Supports intermixed IS and non-IS FLEX I/O modules

  • Galvanic isolation ensures system safety in hazardous environments

  • DIN rail mounting for flexible installation

  • Certified intrinsically safe for use in explosive atmospheres

  • Compact design minimizes panel space requirements

  • LED indicators provide immediate operational status

Applications

  • Hazardous area process control

  • Distributed control systems combining IS and non-IS modules

  • FLEX Ex I/O communication networks

  • Safety-critical industrial automation systems

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more