Skip to content

What are you looking for?


You may also like

AMM22 | Yokogawa Multiplexer Input Module for CENTUM SystemsAMM22 | Yokogawa Multiplexer Input Module for CENTUM SystemsAMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems

AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems


Only 10 left - Selling fast

PRODUCT SKU : AMM22

PRODUCT TYPE : Multiplexer Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AMM22 is a robust multiplexer input module engineered for high-performance data acquisition within CENTUM CS and CENTUM VP distributed control systems. It is designed to efficiently handle multiple field signals—typically millivolt (mV) or thermocouple inputs—by multiplexing them into a single processing channel. This module addresses the critical need for high-density signal monitoring in space-constrained control panels, offering a 1 kHz high-speed conversion rate that ensures rapid and accurate data capture for dynamic industrial processes.

Technical Specifications

The AMM22 is built to withstand rigorous industrial environments while maintaining signal integrity.

Parameter Specification
Product Type Multiplexer Input Module
Model Number AMM22
Compatible Systems CENTUM CS, CENTUM VP
Conversion Speed 1 kHz (High-Speed)
Standard Output Signal 4-20 mA DC
Power Supply 24 V DC
Operating Temperature -10°C to +55°C
Dimensions 28 cm x 21 cm x 2 cm
Weight 1 kg

Model Code Interpretation

Understanding the suffix logic is essential for ensuring compatibility with your specific carrier and wiring setup.

Part Number: AMM22T

AMM22-AXX

  • A (Suffix -T): This suffix typically designates the Terminal Type.

    • -T: Indicates that the module features screw terminals for direct field wiring. This is distinct from the "-C" (Connector) version, which requires a specific mating cable.

    • Note: If your part number is AMM22M, the "M" often denotes a specific "Modified" or "Metric" version tailored for specific regional standards or carrier types.

Note: Always verify the physical interface (Terminal vs. Connector) against your control cabinet wiring to ensure a proper fit.

Installation and Wiring Guidelines

Proper installation is key to maximizing the performance of the AMM22 module.

  1. Carrier Compatibility: The AMM22 is designed to mount into specific I/O carrier boxes (such as the AMN series). Ensure the module is firmly seated in the slot and the locking mechanism is engaged to maintain backplane connectivity.

  2. Wiring Connections:

    • Signal Inputs: For the AMM22T (Terminal type), use a screwdriver to secure the field wires. Ensure the wire gauge matches the terminal specifications to prevent loose connections.

    • Thermocouple/MV: Since this module typically handles low-level signals, use shielded twisted-pair cables to minimize electromagnetic interference (EMI).

    • Grounding: Connect the shield to the ground terminal at the cabinet end to prevent noise from affecting the measurement accuracy.

  3. Power Supply: The module operates on a standard 24 V DC supply. Verify that the system power rail is stable and within the specified range before powering up the module.

  4. Thermal Management: Ensure adequate airflow around the module. The operating temperature range is -10°C to +55°C; exceeding this limit can cause drift in the high-speed conversion accuracy.

Frequently Asked Questions (FAQ)

Q: What is the primary function of the AMM22?A: The AMM22 acts as a multiplexer, allowing the system to scan and process multiple input channels (such as thermocouples or mV signals) sequentially using a single analog-to-digital converter, which increases channel density and efficiency.

Q: What does the "1 kHz" specification mean?A: This refers to the high-speed conversion rate. The module can sample and convert input signals at a rate of 1,000 times per second, making it suitable for processes requiring faster data updates.

Q: Is the AMM22 compatible with CENTUM VP?A: Yes, the AMM22 is designed for use in both CENTUM CS and the newer CENTUM VP systems, providing a reliable migration path for control system upgrades.

Q: Can I use this module for 4-20 mA inputs?A: While the standard output signal is listed as 4-20 mA DC (referring to the internal bus communication or converted signal), the AMM22 is primarily an input module for low-level signals like mV or Thermocouples. For direct 4-20 mA input, other models like the AMM42 or AAM10 series might be more appropriate depending on the specific application.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more