Skip to content

What are you looking for?


You may also like

Allen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input ModuleAllen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input ModuleAllen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input Module
Allen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input Module
Allen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input Module
Allen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input Module

Allen-Bradley SLC 500 1746-IG16 16-Channel TTL DC Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1746-IG16

PRODUCT TYPE : Digital DC Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

Allen-Bradley SLC 500 Digital Input Module – Model: 1746-IG16  The 1746-IG16 is a 16-point TTL DC input module designed for the Allen-Bradley SLC 500 series. It is engineered to handle low-voltage DC signals, making it suitable for TTL and BCD input applications. With fast signal response times, low power consumption, and compatibility with removable terminal blocks, this module provides reliable performance in industrial automation environments.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Product Line: SLC 500

  • Model: 1746-IG16

  • Type: Digital DC TTL Input Module

  • Number of Inputs: 16 channels

  • Voltage Range: 4.5–5.5 VDC (source)

  • Nominal Input Voltage: 5 VDC

  • Backplane Current (5 VDC): 140 mA

  • Signal Delay: 0.25 ms or 0.5 ms selectable

  • Step Response: 100 ms input, 2.5 ms output

  • Watts per Point: 0.02 W

  • Minimum Power Consumption: 0.7 W

  • Total Power Consumption: 1 W

  • Compatible I/O Connections: 1746-HT, 1746-HCA

  • Removable Terminal Block: 1746-RT25B

  • Optional Octal Kit: 1746-RL42

  • Slot Width: 1

  • Enclosure Type: Open-style

  • Weight: 0.50 lbs (0.23 kg)

Application Scenarios

  • TTL and BCD input signal processing in SLC 500 systems

  • Machine-level control requiring fast response times

  • Compact I/O configurations with low-voltage DC inputs

  • Legacy automation systems needing reliable discrete input modules

FAQ

Q: How many inputs does the 1746-IG16 support?  A: It provides 16 TTL DC input channels.

Q: What is the input voltage range?  A: 4.5–5.5 VDC.

Q: Which terminal blocks are compatible?  A: 1746-RT25B removable terminal block.

Q: What applications is this module suited for?  A: TTL and BCD input applications in SLC 500 systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more