Skip to content

What are you looking for?


You may also like

Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input ModuleAllen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input ModuleAllen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module
Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module

Allen Bradley Flex I/O 1794 Series 1794-IE8H 8-Channel HART Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IE8H

PRODUCT TYPE : HART Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley Flex I/O 1794 Series 1794-IE8H is an 8-point analog input module designed for HART-enabled applications. It delivers high-resolution signal conversion, configurable data formats, and robust diagnostic indicators. With DIN rail mounting and compatibility with Flex I/O terminal bases, this module provides reliable integration into distributed control systems.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: Flex I/O 1794

  • Catalog Number / Model: 1794-IE8H

  • UPC: 612598323883

  • Product Type: Flex I/O HART Analog Module

  • Weight: 0.31 lbs (0.14 kg)

  • Resolution: 16-bit

  • Conversion Method: Successive approximation

  • Inputs: 8 single-ended, non-isolated channels

  • Absolute Accuracy: ±0.1% full scale at 20 °C (68 °F)

  • Temperature Drift: ±0.05% full scale from 0–55 °C (32–131 °F)

  • Step Response (to 99%): 80 ms

  • Terminal Base Compatibility: 1794-TB3G, 1794-TB3GS

  • Indicators:

    • 8 red fault LEDs

    • 8 yellow channel LEDs

    • 1 green power LED

  • External DC Supply: Nominal 24 VDC

  • Supply Range: 19.0–31.2 VDC (with 5% AC ripple)

  • FlexBus Current Draw: 80 mA @ 5 VDC

  • Functional Data Range: >17 V @ 22 mA

  • Isolation Voltage: 50 V continuous

  • Power Dissipation: 3.9 W max @ 31.2 VDC

  • Thermal Dissipation: 13.5 BTU/hr max @ 31.2 VDC

  • Mounting: DIN rail

  • Enclosure Type: Open-style

Application Scenarios

  • Distributed control systems requiring HART-enabled analog input

  • Process industries with multiple sensor integration

  • Environments needing diagnostic indicators for fault detection

FAQ

Q: How many analog inputs does the 1794-IE8H support?  A: Eight single-ended, non-isolated inputs.

Q: What terminal bases are compatible with this module?  A: 1794-TB3G and 1794-TB3GS.

Q: Does the module provide diagnostic indicators?  A: Yes, it includes fault, channel, and power LEDs.

Comparison with Similar Models

  • 1794-IE8H: 8-channel HART analog input, 16-bit resolution.

  • 1794-IE4XOE2: Combination analog input/output module.

  • 1794-IF8: 8-channel analog input without HART functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more