Skip to content

What are you looking for?


You may also like

Allen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input ModuleAllen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input ModuleAllen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input Module
Allen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input Module
Allen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input Module
Allen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input Module

Allen-Bradley ArmorPoint 1738-IE4CM12 4-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1738-IE4CM12

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1738-IE4CM12 is a high-precision 4-channel analog input module from the ArmorPoint series. Designed for 24V DC systems, it provides accurate signal acquisition for industrial control and automation applications. Its advanced filtering, notch, and rejection capabilities make it ideal for measuring 4–20 mA or 0–20 mA analog signals with minimal noise interference.

Key Features

  • Channels: 4 single-ended, non-isolated analog inputs

  • Input Voltage: 24V DC nominal

  • Signal Compatibility: Supports standard 4–20 mA and 0–20 mA currents

  • High Accuracy: ±0.1% full-scale at 25°C

  • Stability: 30 ppm/°C current input drift

  • Digital Filtering: Configurable 0–10,000 ms (default 0 ms)

  • Noise Rejection: 120 dB common-mode, -60 dB normal-mode

  • Conversion Type: Sigma-Delta analog-to-digital conversion

  • Input Impedance: 60 Ω

Notch Filter Options

  • 60 Hz (default): 15.7 Hz bandwidth

  • 50 Hz: 13.1 Hz

  • 100 Hz: 26.2 Hz

  • 120 Hz: 31.4 Hz

  • 200 Hz: 52.4 Hz

  • 240 Hz: 62.9 Hz

  • 300 Hz: 78.6 Hz

  • 400 Hz: 104.8 Hz

  • 480 Hz: 125.7 Hz

Technical Specifications

Manufacturer: Allen-Bradley
Brand: Allen-Bradley
Part Number: 1738-IE4CM12
Product Type: ArmorPoint 4-Channel Analog Input Module

Electrical

  • Input Points: 4

  • Input Type: Single-ended, non-isolated

  • Accuracy: ±0.1% FS @ 25°C

  • Accuracy Drift: 30 ppm/°C

  • Conversion Type: Sigma-Delta

  • Input Impedance: 60 Ω

Filter & Rejection

  • Digital Filter: 0–10,000 ms

  • Common Mode Rejection: 120 dB

  • Normal Mode Rejection: -60 dB

  • Notch Frequencies: 50–480 Hz

Environmental & Physical

  • Operating Voltage: 24V DC

  • Mounting: ArmorPoint compatible

  • Weight: Approx. 0.2–0.3 kg (depending on configuration)

Applications

  • Process control systems requiring precise analog measurements

  • Monitoring 4–20 mA current loops in distributed I/O networks

  • Environmental or utility control systems with noise suppression requirements

  • Industrial automation projects where signal integrity is critical

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more