Product Description

The Allen-Bradley 2085-IF8 is an analog input expansion module for the Micro850 series controllers. It provides eight high-resolution input channels, supporting both current and voltage signals. Designed for sensor and transmitter integration, the module uses delta-sigma conversion for precise measurement and offers fast update rates for real-time applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line Micro850

  • Product Type Analog Input Module

  • Part Number 2085-IF8

  • Weight 0.63 lbs (0.28 kg)

  • Number of Channels 8 analog input channels

  • Current Input Range 0–20 mA

  • Voltage Input Range ±10 VDC

  • Input Configuration Bipolar

  • Resolution High-resolution conversion

  • Conversion Method Delta-sigma

  • Channel Isolation Non-isolated

  • Update Rate Fast response for real-time monitoring

  • Status Indication Module LED indicators

  • Wiring Method Terminal block connection

  • Typical Applications Sensor integration, transmitter signal acquisition

Application Scenarios

  • Industrial automation systems requiring multiple analog inputs

  • Sensor and transmitter monitoring in process control environments

  • Applications needing high-resolution signal acquisition with fast update rates

  • Expansion of Micro850 controllers for analog signal handling

FAQ

Q: How many channels does the 2085-IF8 provide?  A: It provides 8 analog input channels.

Q: What input ranges are supported?  A: Current inputs from 0–20 mA and voltage inputs from ±10 VDC.

Q: Is channel isolation provided?  A: No, the channels are non-isolated.

Comparison with Similar Models

  • 2085-IF4: Provides 4 analog input channels, suitable for smaller applications.

  • 2085-IF8: Offers 8 channels for expanded input capacity.

  • 2085-OF4: Analog output module for signal generation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more