Overview
The Allen-Bradley 1771-IBD is a 16-Point Digital Input Module designed for use with the PLC-5 series. This module is engineered to handle input voltage ranges from 10V to 30V DC, offering a reliable solution for industrial control systems. With its versatile input characteristics and efficient power dissipation, the 1771-IBD module ensures stable, high-performance operation in a variety of industrial environments.

Key Features

  • Model Number: 1771-IBD

  • Manufacturer: Allen-Bradley

  • Product Line: PLC-5

  • Product Type: 16-Point Digital Input Module

  • Input Voltage Range: 10V to 30V DC

  • Minimum Input Current:

    • 4.5 mA @ 10V DC

    • 15 mA @ 30V DC

  • Off-state Current: 2.0 mA @ 5V DC

  • Input Impedance: 2.2K ohms (maximum)

  • Propagation Delay:

    • Low to High: 1 ms

    • High to Low: Selectable 1 ms or 6 ms

  • Power Dissipation:

    • Maximum: 7.3 Watts

    • Minimum: 1.0 Watts

  • Thermal Dissipation:

    • Maximum: 24.7 BTU/hr

    • Minimum: 3.4 BTU/hr

  • Backplane Current: 130 mA @ 5V DC (+5%)

  • Maximum Off-state Voltage: 5V DC

  • Minimum On-state Voltage: 10V DC

Applications
The 1771-IBD module is designed for use in industrial automation and control systems, particularly in environments requiring robust digital input processing. With its wide input voltage range and efficient current management, it’s ideal for applications in manufacturing, process control, and other industries where reliable and fast digital inputs are essential.

FAQs
Q: What voltage range does the 1771-IBD module support?
A: The 1771-IBD supports a voltage range of 10V to 30V DC, making it highly flexible for a variety of industrial input configurations.

Q: How long does the 1771-IBD take to process input signals?
A: The 1771-IBD features a 1 ms low to high propagation delay and offers a selectable 1 ms or 6 ms high to low delay, ensuring efficient response times in control systems.

Q: What is the power consumption of the 1771-IBD module?
A: The 1771-IBD has a maximum power dissipation of 7.3 Watts, ensuring that the module operates efficiently without overheating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more