Skip to content

What are you looking for?


You may also like

Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output ModuleAllen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output ModuleAllen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module
Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module
Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module
Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module

Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1762-OB8

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1762-OB8 Ser A is an 8-channel digital output module for the MicroLogix series. It provides reliable DC output control with robust protection against environmental stresses and electrical noise. Designed for use in hazardous and standard industrial locations, this compact module ensures precise and safe signal switching.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model Number: 1762-OB8

  • Product Type: MicroLogix Digital Output Module

  • Module Height x Width x Depth: 90 × 40 × 87 mm (overall height including mounting tabs: 110 mm)

  • Shipping Weight: 210 g (0.46 lbs)

  • Operating Temperature: 0–55°C (32–131°F)

  • Storage Temperature: -40–85°C (-40–185°F)

  • Operating Humidity: 5–95% non-condensing

  • Maximum Operating Altitude: 2000 m (6561 ft)

  • Hazardous Environment Rating: Class I, Division 2, Groups A-D; compliant with ISA/ANSI 12.12.01 and C-UL under CSA C22.2 No. 213

  • Electrical Noise Immunity: Meets NEMA ICS 2-230, EN50081-2 Class A

  • ESD Immunity (EN61000-4-2): 4 kV contact, 8 kV air, 4 kV indirect

  • Radiated Immunity (EN61000-4-3): 10 V/m, 80–1000 MHz, 80% amplitude modulation

  • Fast Transient Burst (EN61000-4-4): 2 kV, 5 kHz

  • Surge Immunity (EN61000-4-5): 2 kV common mode, 1 kV differential mode

  • Conducted Immunity (EN61000-4-6): 10 V, 0.15–80 MHz

Key Features

  • 8 isolated digital outputs for MicroLogix series controllers

  • Compact form factor with mounting tabs for easy installation

  • Resistant to vibration, shock, and extreme temperatures

  • Conforms to hazardous location safety standards

  • Built-in immunity against ESD, surges, fast transients, and radiated noise

Application Scenarios

  • Small to medium discrete control applications

  • Switching DC loads such as relays, solenoids, and indicator devices

  • Deployment in both standard and hazardous industrial zones

  • Integration with MicroLogix controllers in control panels or cabinets

FAQ

Q1: How many outputs does the 1762-OB8 Ser A provide?
A1: The module provides 8 isolated digital outputs.

Q2: Can it operate in hazardous locations?
A2: Yes, it is certified for Class I, Division 2 environments, Groups A–D.

Q3: What protection does it have against electrical noise?
A3: It meets NEMA ICS 2-230, EN50081-2 Class A, and IEC 61000 series for ESD, surge, fast transient, and radiated immunity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more