Only 10 left - Selling fast

PRODUCT SKU : 1756-IR6I

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1756-IR6I is a six-channel temperature-measuring analog module designed for Allen-Bradley ControlLogix systems. Each input is individually isolated, enabling precise and stable RTD measurements. This module supports high-resolution signal acquisition with advanced Sigma-Delta conversion and ensures long-term reliability under industrial environmental conditions.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Model / Part Number: 1756-IR6I

  • Module Type: Temperature-Measuring Analog Input Module

  • Input Channels: 6 individually isolated RTD inputs

  • Input Range:

    • 1.87 Ω, 2.000 Ω, 4.000 Ω, 8.000 Ω

  • Resolution: 16-bit

    • 1.87 Ω: 7.7 mΩ/bit

    • 2.000 Ω: 15 mΩ/bit

    • 4.000 Ω: 30 mΩ/bit

    • 8.020 Ω: 60 mΩ/bit

  • Current Draw: 250 mA @ 5.1V, 125 mA @ 24V

  • Backplane Power: 4.25 W

  • Power Dissipation: 4.3 W max, Thermal dissipation 14.66 BTU/hr

  • Channel Bandwidth: 15 Hz

  • Settling Time: <80 ms to 5% full scale

  • Calibrated Accuracy (@ 25 °C): Better than 0.1% of range

  • Calibration Interval: 6 months

  • Offset Drift: 10 mΩ/°C

  • Gain Drift: Nominal 50 ppm/°C, Maximum 90 ppm/°C

  • Module Error: 0.54% of range

  • Module Scan Time:

    • 25 ms minimum (floating point, ohms)

    • 50 ms minimum (floating point, temperature)

    • 10 ms minimum (integer, ohms)

  • Data Format: Integer mode (left justified, 2’s complement) and IEEE 32-bit floating point

  • Conversion Method: Sigma-Delta

  • Isolation Voltage: 50 V continuous, tested 1350 V AC for 2 s

  • Module Keying: Electronic, software configurable

  • RTB Keying: User-defined mechanical

  • Slot Width: 1

  • Temperature Codes: North American T4A, IEC T4

  • Enclosure: Open-style

Application Notes

  • Designed for precise temperature measurement using RTD sensors

  • Compatible with Allen-Bradley ControlLogix systems

  • Ideal for process control, environmental monitoring, and industrial automation requiring high-resolution analog inputs

FAQ

Q: How many channels does the 1756-IR6I support?
A: Six individually isolated RTD inputs.

Q: What is the calibrated accuracy?
A: Better than 0.1% of full scale at 25 °C.

Q: Is the module isolated?
A: Yes, each input is isolated from the backplane and from other channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more