Overview

The Allen-Bradley 1756-IA16I is a ControlLogix isolated AC input module engineered for reliable monitoring and control in industrial automation systems. Equipped with 16 individually isolated inputs, it ensures safe signal separation and prevents cross-channel interference. The module operates within a broad AC voltage range, making it suitable for a variety of 120V AC applications.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IA16I

  • Product Type: ControlLogix Isolated Input Module

  • Voltage Category: 120V AC, 50/60 Hz

  • Operating Voltage Range: 74–132V AC

  • Number of Inputs: 16, individually isolated

  • Removable Terminal Blocks: Compatible with 1756-TBCH, 1756-TBS6H

  • Power Dissipation (Max): 4.9 W @ 60°C (140°F)

  • Isolation Voltage: 125V continuous; tested to 1200V AC for 2 seconds

  • Mounting: DIN rail or panel mount within standard ControlLogix chassis

  • Weight: 0.22 kg

Key Features

  • 16 fully isolated AC input channels for accurate signal monitoring

  • Compatible with standard ControlLogix terminal blocks for flexible installation

  • High isolation rating to protect backplane and adjacent modules

  • Low power consumption and compact 1-slot design for efficient chassis usage

Applications

  • Monitoring 120V AC signals in control panels

  • Industrial process automation requiring isolated input detection

  • Integration into ControlLogix chassis for distributed control systems

FAQs

Q1: How many inputs does the 1756-IA16I support?
The module supports 16 individually isolated AC inputs for reliable monitoring.

Q2: What is the isolation voltage?
Rated at 125V continuous, and tested to 1200V AC for 2 seconds to ensure channel and backplane protection.

Q3: Which terminal blocks are compatible?
Removable blocks 1756-TBCH and 1756-TBS6H can be used for installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more