Skip to content

What are you looking for?


You may also like

Allen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output ModuleAllen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output ModuleAllen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output Module
Allen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output Module
Allen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output Module
Allen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output Module

Allen-Bradley 1746SC-INO4VI SLC 500 4-Channel Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1746SC-INO4VI

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1746SC-INO4VI acts as a high-performance analog control interface for the SLC 500 platform. This specialty module provides four independent, fully isolated analog output channels capable of driving both current and voltage signals. We supply this unit as 100% Brand New original factory stock, specifically designed for applications that require 16-bit high-resolution precision in complex loop control. By integrating channel-to-channel isolation, the 1746SC-INO4VI eliminates ground loop interference and protects the SLC backplane from field-side electrical transients.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line SLC 500 / 1746 Series
Output Channels 4 Isolated Channels
Resolution 16-bit
Current Signals 0-20 mA, 4-20 mA, 0-21 mA
Voltage Signals 0-5V, 1-5V, 0-10V, ±10V
Accuracy (Current) 0.08% of Full Scale @ 25°C
Isolation Voltage 500V AC Continuous (Channel-to-Channel & Field-to-Backplane)
Step Response Time 1 ms (to 95% of Full Scale)
Backplane Current 120 mA @ 5V DC; 250 mA @ 24V DC
Thermal Dissipation 5.0 Watts (Maximum)
Weight 1.00 lbs (0.45 kg)

Engineering Advantages

  • Superior Noise Immunity: The 1746SC-INO4VI features 500V AC continuous channel-to-channel isolation. This hardware barrier prevents electrical noise or potential differences from one field device from affecting the signals of the other three channels, ensuring stable operation in heavy industrial environments.

  • Ultra-Fast Response for Closed Loops: With a 1 ms step response time, this module executes signal changes almost instantaneously. This high-speed capability allows for more aggressive PID tuning and tighter control over fast-acting valves, dampers, or variable speed drives.

  • High-Resolution Signal Control: The 16-bit architecture divides the output range into 65,536 distinct steps. This granularity enables the PLC to make micro-adjustments to field equipment, significantly improving process consistency and product quality.

  • Streamlined Single-Slot Design: Despite providing four isolated outputs, the module occupies only a single slot in any 1746 SLC chassis. This density maximizes your I/O capacity without requiring the purchase of additional chassis or power supplies.

  • Exceptional Thermal Stability: High-quality internal components maintain a non-linearity rating of 0.02% across the operating temperature range. This prevents "signal drift," reducing the need for frequent recalibration of field actuators.

FAQs

  • Can I mix current and voltage outputs on the same module?

    Yes. Each of the four isolated channels functions independently. You can configure one channel for a 4-20 mA current loop while setting another for a ±10V voltage signal to meet diverse field requirements.

  • Does this module require an external power supply?

    The 1746SC-INO4VI draws 250 mA at 24V DC from the SLC backplane. Ensure your SLC power supply (e.g., 1746-P1, P2, or P4) has sufficient current headroom to support this module along with your other I/O cards.

  • How does this module differ from the standard 1746-NO4I?

    The "SC" (Specialty Component) designation indicates enhanced features. Unlike standard non-isolated modules, the 1746SC-INO4VI provides full channel-to-channel isolation and higher 16-bit resolution, whereas standard modules often share a common return and lower resolution.

  • Is this a genuine factory-new unit?

    Yes. We guarantee this product is 100% Brand New. It ships in original manufacturer packaging with intact factory seals, ensuring it has never seen field service or environmental exposure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.