Skip to content

What are you looking for?


You may also like

Allen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output ModuleAllen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output ModuleAllen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output Module
Allen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output Module
Allen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output Module
Allen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output Module

Allen Bradley 1734-OW4 | POINT I/O 4-Point Relay Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1734-OW4

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1734-OW4 POINT I/O module provides four isolated electromechanical relay outputs, designed for flexible digital output control in distributed automation systems. Each channel uses Form A (normally open) contacts, offering reliable switching for both AC and DC loads. With robust isolation, compact design, and long contact life, this module is well-suited for industrial applications requiring dependable relay-based output control.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line POINT I/O

  • Product Type Digital Output Module

  • Part Number 1734-OW4

  • Outputs per Module 4 Form A isolated (NO) relay contacts

  • Off-State Leakage Current Max 1.2 mA @ 240 V AC (with bleed resistor through snubber circuit)

  • Backplane Power 5 V DC, 90 mA

  • Power Consumption 0.8 W

  • Power Dissipation Max 0.5 W

  • Contact Ratings

    • 120/240 V AC, 2.0 A @ 50/60 Hz

    • 1800 VA make, 180 VA break

    • 5–30 V DC, 2.0 A, R150

  • Isolation Voltage 250 V, tested at 2550 V DC for 60 s (field-to-system and between contact sets)

  • Switching Frequency Max 1 operation per 3 s (0.3 Hz @ rated load)

  • Electrical Contact Life Minimum 100,000 operations @ rated load

  • Wiring Category Category 1 (signal ports)

  • Wire Size 0.25–2.5 mm² (22–14 AWG), solid or stranded copper, rated 85 °C or higher, insulation max 1.2 mm

  • Terminal Base Screw Torque Determined by installed terminal block

  • Weight 0.06 kg

Application Scenarios

  • Relay-based digital output control in distributed POINT I/O systems

  • Switching AC or DC loads in industrial automation panels

  • Applications requiring isolated relay contacts for safety and reliability

FAQ

Q: How many relay outputs does the 1734-OW4 provide?  A: It includes four Form A (normally open) isolated relay outputs.

Q: What is the expected contact life?  A: At least 100,000 operations under rated load conditions.

Q: What isolation voltage is supported?  A: 250 V, tested at 2550 V DC for 60 seconds.

Comparable Models

  • 1734-OW4: 4-point relay output module (this model)

  • 1734-OB8: 8-point DC transistor output module

  • 1734-OV4: 4-point DC sinking output module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more