Skip to content

What are you looking for?


You may also like

ABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination UnitABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination UnitABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination Unit
ABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination Unit
ABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination Unit
ABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination Unit

ABB TU830V1 3BSE013234R1 S800 I/O Extended Module Termination Unit


Only 10 left - Selling fast

PRODUCT SKU : TU830V1 3BSE013234R1

PRODUCT TYPE : Module Termination Unit

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The TU830V1 3BSE013234R1 is designed for 8-channel modules requiring individual signal termination. It has three rows of screw terminals (24 total) for dedicated signal, return, and power connections, eliminating the need for external terminal blocks. As a passive component, it ensures reliability without active electronics. The unit supports hot-swapping for live system maintenance, and its mechanical keying system prevents incorrect module insertion, ensuring safe operation.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Sweden

  • Model Number: TU8130V1

  • Order Number: 3BSE013234R1

  • Product Type: Extended Module Termination Unit (MTU)

  • Weight: 0.45 kg

  • Termination Capacity: 24 Screw Terminals (3 rows)

  • Maximum Rated Voltage: 50 V DC

  • Maximum Rated Current: 2 A per channel

  • Wire Range Capacity: 0.2 to 2.5 mm² (24-12 AWG)

  • Mounting Configuration: 35mm standard DIN rail

  • Ingress Protection: IP20

Features

  • Extended Terminal Density: Provides 24 independent screw-clamp terminals, supporting 3-wire field device configurations with dedicated signal and return paths.

  • Passive Backplane Integrity: Engineered as a non-electronic base to maximize the Mean Time Between Failures (MTBF) and provide a transparent electrical signal path.

  • Live System Hot-Swapping: Enables the removal and insertion of active I/O modules while the cluster remains energized, ensuring zero-downtime during maintenance.

  • Mechanical Safety Keying: Incorporates physical coding pins to ensure only compatible I/O modules are seated, safeguarding the internal bus from incorrect hardware installation.

  • Streamlined Power Distribution: Features integrated terminals for shared voltage supply and grounding, reducing the complexity of cabinet internal wiring.

  • Industrial Durability: Built to withstand high-vibration and diverse thermal environments, ensuring stable electrical contact in heavy industrial settings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more