ABB NKAS01-L5 Analog Module Termination Unit CableABB NKAS01-L5 Analog Module Termination Unit CableABB NKAS01-L5 Analog Module Termination Unit Cable
ABB NKAS01-L5 Analog Module Termination Unit Cable
ABB NKAS01-L5 Analog Module Termination Unit Cable
ABB NKAS01-L5 Analog Module Termination Unit Cable

ABB NKAS01-L5 Analog Module Termination Unit Cable


Only 10 left - Selling fast

PRODUCT SKU : NKAS01-L5

PRODUCT TYPE : I/O Cables

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB NKAS01-L5, also cataloged as the NKAS01-L5 Analog Module Termination Unit Cable, operates as a dedicated hardware component for analog signal transmission and field interface interconnections within ABB INFI 90 / Network 90 termination unit assemblies.

Hardware Specifications

Parameter Specification
Model NKAS01-L5
Brand ABB
Origin USA / Sweden
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive cable assembly (no power draw)
Cable Type Analog Module TU Cable
Conductor Material High-quality copper
Insulation Material Durable heat-resistant insulation
Voltage Rating Low-voltage industrial rating

Deterministic Network Backplane and Signal Interconnects

The NKAS01-L5 cable assembly bridges analog I/O processing cards and field termination units, maintaining precise 4-20 mA or low-voltage DC loop integrity without signal degradation. The low-resistance copper conductor geometry minimizes impedance variations across high-density I/O configurations.

Firmware flash compatibility across connected analog modules remains unhindered due to passive pin-to-pin signal path execution. High-density shielding limits cross-channel capacitive coupling, ensuring that real-time backplane bus communication velocity and analog sampling rates meet system loop execution criteria.

Frequently Asked Questions

Q: Does the NKAS01-L5 cable draw operating current from the subrack backplane power rail?

A: No, the NKAS01-L5 is a passive cable assembly designed exclusively for signal routing between analog modules and termination units.

Q: What insulation performance limits apply to the cable construction?

A: The cable utilizes heat-resistant insulation designed for continuous operation within an ambient temperature range of -20 deg C to +70 deg C.

Q: Can the cable be hot-swapped while field loops are active?

A: Field analog loops connected to the termination unit should be de-energized or set to manual override before disconnecting the cable to avoid transient spikes on active signal channels.

Field Installation Guidelines

  • Ensure all associated field loops and analog input/output circuits are isolated prior to connecting or disconnecting the cable assembly.
  • Route the cable through designated wireways, maintaining separation from high-voltage AC power lines to prevent electromagnetic interference.
  • Avoid bending the cable beyond its minimum recommended bend radius during cabinet installation to preserve internal conductor layout.
  • Fully engage both terminal connector locking screws to secure ground continuity and prevent signal dropouts caused by mechanical vibration.
  • Inspect field termination block screws for correct torque before restoring low-voltage power to the analog module loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more