Skip to content

What are you looking for?


You may also like

AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-ChannelAAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-ChannelAAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel

AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel


Only 10 left - Selling fast

PRODUCT SKU : AAI543-H50/A4S00

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI543-H50 / A4S00 analog output module from Yokogawa is engineered for distributed control systems requiring precise and reliable signal transmission. With 16 isolated output channels, it delivers 4–20 mA analog signals with high accuracy and stability. The H50 suffix indicates HART protocol support and redundancy capability, while the A4S00 option adds a pressure clamp terminal block (Model: ATA4S-00) for secure and flexible wiring.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI543-H50 / A4S00

  • Type: Isolated Analog Output Module

  • Channels: 16 isolated output channels

  • Output Signal Range: 4–20 mA DC

  • Digital Communication: HART protocol supported

  • Redundancy: Standard switch-over response supported

  • Withstanding Voltage: 1500 V AC (output to system, 1 minute)

  • Allowable Load Resistance: 0–750 Ω

  • Circuit-Open Detection Threshold: <0.65 mA

  • Accuracy: ±0.05% of full scale

  • Response Time: 1 ms

  • Temperature Drift: ±16 µA per 10 °C

  • Operating Temperature Range: -40°C to +85°C

  • Power Consumption: 230 mA @ 5 V DC, 540 mA @ 24 V DC

  • External Connection: Pressure clamp terminal block (ATA4S-00)

  • Dimensions (W × H × D): 170 × 120 × 45 mm

  • Weight: 0.4 kg

Suffix Code Breakdown

  • H: HART communication support

  • 5: Standard switch-over redundancy, no explosion protection

  • 0: Basic hardware type

  • /A4S00: Adds ATA4S-00 pressure clamp terminal block

Key Features

  • High Accuracy: ±0.05% FS ensures precise control signals

  • Fast Response: 1 ms output response for dynamic applications

  • HART Integration: Enables diagnostics and remote configuration

  • Redundancy Support: Fail-safe operation in critical systems

  • Environmental Durability: Wide operating range (-40°C to +85°C)

Application Scenarios

  • Valve and actuator control in chemical plants

  • Power generation and turbine monitoring

  • Water treatment and distribution automation

  • Industrial machinery requiring precise analog actuation

FAQ

Q: How many channels does the AAI543-H50 / A4S00 provide?  A: It supports 16 isolated analog output channels.

Q: What does the suffix “A4S00” indicate?  A: It specifies the inclusion of a pressure clamp terminal block (ATA4S-00).

Q: Is redundancy supported?  A: Yes, the module includes standard switch-over response in redundant setups.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more