Skip to content

What are you looking for?


You may also like

AAI143-S03 | 16-Channel Isolated Analog Input Module by YokogawaAAI143-S03 | 16-Channel Isolated Analog Input Module by YokogawaAAI143-S03 | 16-Channel Isolated Analog Input Module by Yokogawa
AAI143-S03 | 16-Channel Isolated Analog Input Module by Yokogawa
AAI143-S03 | 16-Channel Isolated Analog Input Module by Yokogawa
AAI143-S03 | 16-Channel Isolated Analog Input Module by Yokogawa

AAI143-S03 | 16-Channel Isolated Analog Input Module by Yokogawa


Only 10 left - Selling fast

PRODUCT SKU : AAI143-S03

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-S03 analog input module from Yokogawa is a high-performance unit designed for integration into the CENTUM series distributed control systems. It provides 16 isolated input channels for 4–20 mA DC current signals, ensuring precise measurement and reliable data acquisition. The isolated design prevents interference between channels, making it suitable for complex industrial environments where accuracy and stability are critical.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI143-S03

  • Type: Isolated Analog Input Module

  • Channels: 16 isolated input channels

  • Input Type: Current (4–20 mA DC)

  • Accuracy: High precision measurement

  • Weight: 0.4 kg

  • Power Consumption: 3.5 W

  • Data Update Period: 10 ms

  • Isolation: Channel-to-system isolation for noise immunity

  • Design: Compact and lightweight for easy installation

Key Features

  • 16 Isolated Channels: Prevents cross-channel interference, ensuring signal integrity

  • Optimized for Current Input: Specifically designed for 4–20 mA DC signals

  • Compact Build: Lightweight module for efficient cabinet integration

  • Energy Efficient: Low power consumption at 3.5 W

  • Reliable Performance: Stable operation in demanding industrial environments

Application Scenarios

  • Process monitoring in chemical and petrochemical industries

  • Power generation and turbine instrumentation

  • Water treatment and distribution systems

  • General industrial automation requiring multi-channel current input

FAQ

Q: How many channels does the AAI143-S03 provide?  A: It supports 16 isolated analog input channels.

Q: What type of signals can this module measure?  A: It is designed for 4–20 mA DC current signals.

Q: Is this module suitable for redundant configurations?  A: Yes, it integrates seamlessly into Yokogawa CENTUM systems with redundancy support.

Comparison with Similar Models

  • AAI143-S00: Standard analog input module without extended options

  • AAI143-H53: HART-enabled version with ISA G3 compliance

  • AAI143-S03: Enhanced model with isolated channels and low power consumption

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more