Product Description

The AAI143-H00 analog input module from Yokogawa is designed for distributed control systems requiring precise current signal acquisition. This model provides 16 isolated input channels for 4–20 mA DC signals, ensuring reliable measurement and integration with smart field devices. The H00 suffix indicates HART communication support combined with a basic hardware configuration.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI143-H00

  • Type: Isolated Analog Input Module

  • Channels: 16 isolated input channels

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: 24 mA

  • Withstanding Voltage: 1500 V AC between input and system (1 minute)

  • Input Resistance:

    • Power ON: 270 Ω at 20 mA, 350 Ω at 4 mA

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0 V minimum at 20 mA, 25.5 V maximum at 0 mA (limit 25 mA)

  • Transmitter Configuration: Supports 2-wire and 4-wire transmitters via setting pin

  • Temperature Drift: ±16 µA per 10 °C change

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • Weight: 0.3 kg (Shipping weight: 2.0 kg)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS1 cable

  • Communication Protocol: HART-enabled

Suffix Code Breakdown

  • H: HART communication support

  • 0: Basic hardware type

Key Features

  • Isolated Channels: Ensures reliable signal integrity

  • HART Communication: Enables diagnostics and remote configuration

  • High Accuracy: ±16 µA precision for stable measurement

  • Compact Design: Lightweight and efficient for cabinet installation

Application Scenarios

  • Chemical and petrochemical process monitoring

  • Power generation instrumentation

  • Water treatment and distribution systems

  • Industrial automation requiring isolated multi-channel input

FAQ

Q: How many channels does the AAI143-H00 provide?  A: It supports 16 isolated analog input channels.

Q: What does the suffix “H00” indicate?  A: It specifies HART communication support with a basic hardware configuration.

Q: Is redundancy supported?  A: Yes, the module is compatible with dual-redundant configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more