Product Description

The AAI141-H00 analog input module from Yokogawa is designed to provide accurate and stable signal acquisition for distributed control systems. Supporting HART communication, this module offers 16 non-isolated channels for 4–20 mA DC input signals, making it suitable for monitoring transmitters, sensors, and other field devices. Its compact design, fast response, and robust electrical specifications ensure reliable operation in industrial environments.

Technical Specifications

  • Model Number: AAI141-H00

  • Type: 16-Point Analog Input Module

  • Channels: 16 non-isolated input channels

  • Signal Range: 4–20 mA DC

  • Input Current/Voltage: 27 mA, ±7.5 V, ±13 V

  • Accuracy: ±16 µA

  • Input Resistance (Power ON): 400 Ω at 20 mA, 1000 Ω at 4 mA

  • Input Resistance (Power OFF): ≥500 kΩ

  • Data Update Period: 10 ms

  • Step Response Time: 100 ms

  • Temperature Drift: ±16 µA per 10°C change

  • Transmitter Supply Voltage: ≥14.8 V at 20 mA

  • Current Consumption: 310 mA (5 V DC), 450 mA (24 V DC)

  • External Connections: Pressure clamp terminal, KS cable, MIL connector cable

  • Weight: 0.2 kg

  • Communication Protocol: HART-enabled

Key Features

  • Multi-Channel Input: 16 channels for efficient signal acquisition

  • HART Support: Enables digital communication over analog signals

  • Fast Response: 10 ms update cycle with 100 ms step response

  • Compact and Lightweight: Easy integration into control cabinets

  • Stable Accuracy: Maintains precision across varying temperatures

Application Scenarios

  • Process monitoring in chemical and petrochemical plants

  • Power generation and turbine instrumentation

  • Water treatment and distribution systems

  • General industrial automation requiring multi-channel analog input

FAQ

Q: How many channels does the AAI141-H00 provide?  A: It supports 16 non-isolated analog input channels.

Q: Does this module support HART communication?  A: Yes, it is HART-enabled for digital communication over analog signals.

Q: What is the typical accuracy of the input signals?  A: The accuracy is ±16 µA, ensuring precise measurement.

Comparison with Similar Models

  • AAI141-S00: Standard analog input module without HART support

  • AAI141-H00: Enhanced version with HART-enabled communication

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more