Skip to content

What are you looking for?


You may also like

8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module
8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module
8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module
8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module

8U-TCNT01 51307032-175 Honeywell C300 Controller Input Output Module


Only 10 left - Selling fast

PRODUCT SKU : 8U-TCNT01 51307032-175

PRODUCT TYPE : Input Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for C300 controller I/O signal interfacing and processing within Honeywell Experion PKS Series 8 platforms, the Honeywell 8U-TCNT01 51307032-175 (8U-TCNT01 Controller Input Output Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 8U-TCNT01 51307032-175 (8C-TCNT01 / 8U-TCNT01)
Brand Honeywell
Origin USA
Weight 0.1 kg
Dimensions 2.2 cm x 12.4 cm x 12.6 cm
System Platform Honeywell Experion PKS C300 / Series 8
Component Type Controller Input Output Module

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The controller I/O module assembly establishes real-time signal routing between field I/O devices and the C300 control processor. Galvanic channel-to-channel isolation decouples field-side instrument noise and ground potential loops from internal controller buses. Superimposed 4-20 mA HART signal pass-through capabilities enable direct transport of field device diagnostics and secondary process variables to system monitoring logic without disturbing loop execution times.

Frequently Asked Questions

Q: How does the 8U-TCNT01 terminal assembly connect to the 8C-TCNT01 module hardware?

A: The 8C-TCNT01 logic module mounts directly onto the 8U-TCNT01 IOTA baseplate, connecting through integrated backplane pins to separate control logic from field wiring terminals.

Q: What mechanisms isolate the 51307032-175 assembly from field electrical noise?

A: Channel-to-channel galvanic isolation barriers block transient switching surges and circulating ground currents from affecting internal processing circuits.

Q: What are the physical housing dimensions and weight for the assembly?

A: The module unit measures 2.2 cm x 12.4 cm x 12.6 cm and weighs 0.1 kg.

Field Installation Guidelines

  1. Disconnect backplane power to the C300 carrier base before installing or removing the 8C-TCNT01 logic module assembly.
  2. Wear a grounded wrist strap during installation to protect sensitive electronic components from static electricity.
  3. Align the module housing guide pins with the 8U-TCNT01 IOTA platform and seat the unit firmly until mechanical latches engage.
  4. Route field signal cabling separately from high-voltage AC power conductors to avoid inductive coupling and signal distortion.
  5. Ground cable shield wires at a single point on the main cabinet earth ground bar to maintain signal integrity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more