Skip to content

What are you looking for?


You may also like

8U-PWSP02-CN Honeywell Series 8 Digital Output Module8U-PWSP02-CN Honeywell Series 8 Digital Output Module8U-PWSP02-CN Honeywell Series 8 Digital Output Module
8U-PWSP02-CN Honeywell Series 8 Digital Output Module
8U-PWSP02-CN Honeywell Series 8 Digital Output Module
8U-PWSP02-CN Honeywell Series 8 Digital Output Module

8U-PWSP02-CN Honeywell Series 8 Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : 8U-PWSP02-CN

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 8U-PWSP02-CN, also cataloged as the 8U-PWSP02-CN Digital Output Module, operates as a dedicated hardware component for field load switching and discrete channel excitation within Honeywell Experion PKS Series 8 platforms.

Hardware Specifications

Parameter Specification
Model 8U-PWSP02-CN
Brand Honeywell
Origin USA
Weight 2.0 kg (Shipping)
Output Voltage Range 21 to 29 VDC
Continuous Current 5 A maximum
Module Type Digital Output Module

Channel-to-Channel Isolation & 24 VDC Power Distribution

The module manages discrete output power distribution, driving relays, solenoid valves, and indicator circuits within an operating range of 21 to 29 VDC. Galvanic channel-to-channel isolation prevents transient electrical surges, ground potential shifts, and inductive switching spikes on field wiring from propagating to internal controller backplane buses. Integrated current-limiting safeguards maintain stable voltage levels across output circuits up to the continuous rating of 5 A.

Frequently Asked Questions

Q: What is the maximum continuous current capacity supported by the 8U-PWSP02-CN output circuits?

A: The module supports a maximum continuous current load of 5 A across its field power distribution terminals.

Q: What operating DC voltage range is permitted for connected field devices?

A: Field power supply lines connected to the module channels must remain within 21 to 29 VDC.

Q: How does the module prevent inductive field spikes from affecting central processing logic?

A: Galvanic isolation circuits separate field output lines from internal backplane logic, suppressing electrical transients and noise coupling.

Field Installation Guidelines

  1. Isolate power from the Series 8 carrier assembly or rack before seating or unseating the 8U-PWSP02-CN module.
  2. Wear an ESD grounding strap during module handling to protect internal semiconductor components from static discharge.
  3. Align the module card edge with the designated slot and press firmly until retention mechanisms latch completely.
  4. Route field output cabling in separate cable trays away from high-voltage AC lines to prevent inductive noise coupling.
  5. Terminate signal shields at a single ground bus bar and ensure field load currents remain within the maximum 5 A continuous specification.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more