Skip to content

What are you looking for?


You may also like

8C-PAIMAI | Honeywell | 8-Channel Analog Input Module8C-PAIMAI | Honeywell | 8-Channel Analog Input Module8C-PAIMAI | Honeywell | 8-Channel Analog Input Module
8C-PAIMAI | Honeywell | 8-Channel Analog Input Module
8C-PAIMAI | Honeywell | 8-Channel Analog Input Module
8C-PAIMAI | Honeywell | 8-Channel Analog Input Module

8C-PAIMAI | Honeywell | 8-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 8C-PAIMAI

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Honeywell 8C-PAIMAI is an industrial-grade analog input module designed to collect and transmit precise analog signals for advanced automation systems. It provides reliable data acquisition for process control and monitoring applications.

Technical Specifications

  • Model Number: 8C-PAIMAI

  • Product Type: Analog Input Module

  • Input Channels: 8 differential analog channels

  • Supported Input Signals: 4–20 mA DC, 0–20 mA DC, 0–10 V DC, ±10 V DC

  • Measurement Accuracy: ±0.1% of full scale at 25°C

  • Operating Temperature Range: –40°C to +70°C

  • Power Supply: 24 V DC ±10%

  • Typical Power Consumption: 50 mA

  • Isolation Performance: Channel-to-channel 250 V AC rms; Power-to-signal 500 V AC rms

  • Response Time: ≤100 ms (90% step response)

  • Storage Temperature Range: –40°C to +85°C

  • Humidity Tolerance: 5–95% RH (non-condensing)

  • Dimensions: 5.1 × 26.7 × 17.8 cm

  • Weight: 0.3 kg

Key Features

  • High-precision signal acquisition ensures reliable and stable data

  • Compatible with multiple analog input types for versatile deployment

  • Industrial-grade construction with strong environmental resistance

  • Differential channel isolation reduces noise interference

  • Designed for integration into Honeywell Series 8 automation systems

Applications

  • Temperature, pressure, and flow monitoring in industrial processes

  • Data acquisition for process automation systems

  • Building management and machine control requiring high-accuracy analog input

  • Systems requiring reliable differential analog input channels with fast response

FAQ

  • Q: How many input channels does the 8C-PAIMAI support?
    A: It provides 8 differential analog input channels.

  • Q: What types of signals are compatible?
    A: Supports 4–20 mA DC, 0–20 mA DC, 0–10 V DC, and ±10 V DC.

  • Q: Can it operate in extreme environments?
    A: Yes, it works from –40°C to +70°C and handles 5–95% RH.

  • Q: Is this module compatible with Honeywell Series 8 systems?
    A: Yes, it integrates seamlessly with Series 8 automation systems.

  • Q: What is the response time?
    A: ≤100 ms for 90% step response, ensuring fast signal acquisition.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more