PRODUCT SKU : 3625А

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Triconex 3625A is a 32-channel digital output module built on Triple Modular Redundancy (TMR) architecture for safety-critical industrial applications. Operating at a nominal voltage of 24 VDC, it converts logic commands into electrical output signals to drive external actuators, valves, solenoids, and indicators.

Output Performance and Electrical Characteristics

The module features 32 commoned digital output points operating over a voltage range of 16 to 32 VDC (with an absolute maximum rating of 36 VDC). Each channel delivers up to 1.7 A of continuous current with a typical voltage drop below 2.8 VDC at full load, and handles short-term surge currents up to 7 A for 10 ms durations.

Fault Tolerance and Protection

Designed with internal self-protection features, the 3625A operates without requiring external overvoltage protection devices. The outputs require a minimum load current of 10 mA for proper state monitoring, exhibit a maximum load leakage current of 4 mA, and maintain overall module power consumption below 13 W.

Parameter Specification
Model 3625A
Brand Triconex
Product Type Digital Output Modules
Architecture Triple Modular Redundancy (TMR)
Output Points 32, commoned
Nominal Voltage 24 VDC
Voltage Range 16-32 VDC
Maximum Voltage 36 VDC
Voltage Drop < 2.8 VDC @ 1.7 A (typical)
Current Rating 1.7 A per point
Surge Current 7 A per 10 ms
Minimum Required Load 10 mA
Load Leakage 4 mA maximum
Power Consumption < 13 W

Frequently Asked Questions

Q: What is the current capacity per channel for the Triconex 3625A module?

A: Each point provides up to 1.7 A continuous current at 16-32 VDC, with a maximum surge capacity of 7 A for 10 ms.

Q: Does the Triconex 3625A require external overvoltage protection?

A: No, the module incorporates a self-protecting design that eliminates the need for external overvoltage protection components.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more