22 100 | HIMA | Safety-Related Output Module22 100 | HIMA | Safety-Related Output Module22 100 | HIMA | Safety-Related Output Module
22 100 | HIMA | Safety-Related Output Module
22 100 | HIMA | Safety-Related Output Module
22 100 | HIMA | Safety-Related Output Module

22 100 | HIMA | Safety-Related Output Module


Only 10 left - Selling fast

PRODUCT SKU : 22100

PRODUCT TYPE : Output Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The 22 100 from HIMA is a high-reliability safety-related output module designed for integration into safety-critical automation systems. It provides secure and monitored output channels for activating actuators, relays, and other field devices while maintaining compliance with stringent functional safety standards. This module ensures consistent and dependable operation in industrial safety environments.

Specifications

  • Model: 22 100

  • Brand: HIMA

  • Output Channels: 4–8 configurable safety output channels (depending on configuration)

  • Output Type: Relay or transistor (depending on module variant)

  • Output Voltage: 24V DC nominal

  • Output Current: Up to 2A per channel

  • Isolation: Channel-to-channel and channel-to-system galvanic isolation

  • Response Time: < 10 ms typical

  • Power Supply: 24V DC ±10%

  • Operating Temperature: -20°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Mounting: DIN rail compatible

  • Diagnostics: Built-in LED indicators per channel for status and fault detection

  • Compliance: SIL 2 / SIL 3 capable depending on system architecture

Features

  • Safety-certified output module for critical industrial applications

  • High-speed, monitored output channels for reliable actuation

  • Compact and modular design for easy integration into HIMA safety racks

  • Built-in diagnostic LEDs for fault detection and maintenance support

  • Designed for harsh industrial environments with wide temperature tolerance

Applications

Ideal for safety instrumented systems (SIS), emergency shutdown systems, process control systems requiring SIL-rated outputs, and integration into HIMA safety automation platforms.

FAQ

Q: How many outputs does the 22100 module support?
A: Configurable 4–8 safety output channels, depending on system setup.

Q: Is this module compatible with HIMA safety racks?
A: Yes, it integrates seamlessly with HIMA safety I/O racks.

Q: What types of outputs are supported?
A: Both relay and transistor outputs depending on module variant.

Q: What safety standards does the module comply with?
A: It supports SIL 2 / SIL 3 functional safety when integrated in a certified system architecture.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more