Skip to content

What are you looking for?


You may also like

216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit
216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit
216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit
216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit

216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit


Only 10 left - Selling fast

PRODUCT SKU : 216DB61 HESG324063R100

PRODUCT TYPE : Binary Input and Tripping Units

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed fault detection and protective action in Procontrol P13 excitation platforms, the ABB 216DB61 HESG324063R100 (216DB61 Binary Input and Tripping Unit) provides direct physical/electrical execution. The module captures field binary signals and drives six high-speed tripping relays with dual contact configurations to perform rapid, redundant fault isolation.

Hardware Specifications

Parameter Specification
Model 216DB61 (HESG324063R100)
Brand ABB
Product Type Binary Input and Tripping Units
Dimensions 22.5 mm x 75 mm x 110 mm
Weight 0.5 kg
Operating Temp -10 to +55 deg C
Power Consumption Internal auxiliary burden dependent on active relay state
Output Contact Config Six tripping relays with dual contact output channels
Protection Features Integrated short-circuit protection and redundant power inputs

Deterministic Networks and Backplane Bus Communication Velocity

The module interfaces directly with subrack backplane communication buses, maintaining low latency execution for high-speed tripping logic. Data frames pass via PROFINET and Modbus TCP/IP industrial networks to central control processors without compromising local relay tripping response times. Integrated firmware flash compatibility guarantees continuous signal processing and rapid fault clearing across synchronized control racks.

Frequently Asked Questions

Q: How does the dual contact configuration on the tripping relays support fault isolation?

A: The dual contact output arrangement allows parallel or series contact wiring to implement redundant tripping paths or dual-channel feedback validation, minimizing the risk of a single contact failure during critical trip events.

Q: Can the 216DB61 be replaced while the host system remains powered?

A: Hot-swapping limits depend on rack backplane architecture; field power to input circuits and high-voltage trip outputs must be isolated prior to removing or inserting the unit to prevent unintended tripping or arc flash transients.

Q: What power redundancy features are supported on this module?

A: The module includes dual power input circuitry to accept redundant DC supply feeds, preventing unit shutdown in the event of an auxiliary power supply drop.

Field Installation Guidelines

  1. Mounting and Physical Placement: Insert the module into the designated 22.5 mm rack seat or DIN rail socket, ensuring the locking mechanisms fully engage to maintain mechanical connection stability.
  2. Signal Cable Shielding: Terminate binary input and trip loop cable shields to the local earth ground bar using low-impedance ground clamps at the panel entry point to suppress electrical noise.
  3. Auxiliary Power Wiring: Connect primary and secondary DC power feeds to the dedicated redundant power terminals according to polarity markings.
  4. Output Contact Isolation: Route high-speed tripping output lines separately from low-voltage digital communication cabling to eliminate inductive crosstalk during relay coil actuation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more