Skip to content

What are you looking for?


You may also like

1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision
1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision
1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision
1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision

1794-TB3G Allen-Bradley FLEX I/O Base Unit with High Precision


Only 10 left - Selling fast

PRODUCT SKU : 1794-TB3G

PRODUCT TYPE : Terminal Base Unit

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1794-TB3G from Allen-Bradley is a FLEX I/O terminal base unit designed to provide reliable digital-to-analog conversion for control systems. Factory-calibrated and supporting multiple output formats, this module delivers precise signal outputs for a range of industrial applications.

Technical Specifications

  • Model: 1794-TB3G

  • Output Resolution: 15-bit plus sign (0.656 µA/cnt, 0.320 mV/cnt)

  • Data Format: 2’s complement, 2’s complement percent, binary, offset binary

  • Output Conversion: Digital-to-analog converter

  • Output Conversion Rate: 2.5 / 5.0 ms

  • Step Response (63% FS): <25 µs

  • Current or Voltage Output: Current load up to 3 mA, resistive voltage load 0–750 Ω

  • Accuracy: 0.1% Full Scale at 25 °C for both current and voltage input

  • Temperature Drift: 0.0025% FS/°C for current input, 0.0012% FS/°C for voltage input

  • Calibration: Factory-calibrated

  • Isolation Voltage: 120V continuous (with 1794-TB2/TB3/TB3S/TB3T/TB3TS), 250V continuous (with 1794-TBN); type tested 1500V AC 60 s, 2550V DC 1 s, channel-to-channel, I/O-to-system

  • Weight: 0.20 kg

Applications

Ideal for extending FLEX I/O systems in industrial automation, the 1794-TB3G is suitable for precise analog output, signal conditioning, and integration with other 1794 terminal bases. It is compatible with control systems requiring fast, accurate digital-to-analog conversion.

FAQ

Q: Can this terminal base handle high-speed analog output?
A: Yes, it supports step response times under 25 µs and output conversion rates of 2.5/5 ms.

Q: Is calibration required before use?
A: No, the 1794-TB3G is factory-calibrated for immediate deployment.

Q: What isolation voltage is supported?
A: It supports up to 120V continuous for standard combinations and 250V continuous with 1794-TBN modules, tested to 1500V AC and 2550V DC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more