Skip to content

What are you looking for?


You may also like

1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels
1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels
1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels
1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels

1794-OB16P FLEX I/O Module | Allen-Bradley | 16 DC Output Channels


Only 10 left - Selling fast

PRODUCT SKU : 1794-OB16P

PRODUCT TYPE : Digital DC Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The Allen-Bradley 1794-OB16P is a FLEX I/O digital DC output module designed to provide 16 independent current sourcing channels for modular automation systems. It ensures reliable DC load control, fast response, and seamless integration with multiple terminal bases. Built for durability, it supports precise actuation in industrial environments and distributed control networks.

Technical Specifications

  • Number of Outputs: 16, current sourcing

  • Output Voltage: 10 V DC min, 24 V DC nominal, 31.2 V DC max

  • Output Current Rating: 8 A total (16 outputs @ 0.5 A each)

  • On-State Current Range: 1 mA to 500 mA per channel

  • Voltage Drop: Max 0.5 V DC

  • Surge Current: 2 A for 50 ms, repeatable every 2 seconds

  • Off-State Leakage Current: Max 0.5 mA per channel

  • Isolation Voltage: 50 V continuous (Basic Insulation), tested at 850 V DC for 1 s

  • Channel Isolation: No isolation between individual channels

  • Signal Delay: Off to On 0.5 ms, On to Off 1.0 ms

  • FlexBus Current: 80 mA @ 5 V DC

  • Max Power Dissipation: 5.3 W @ 31.2 V DC

  • Thermal Dissipation: 18.1 BTU/hr @ 31.2 V DC

  • Terminal Base Compatibility: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK

  • Fusing: Outputs are not internally fused; external fusing recommended using SAN-0 MQ4-800mA

Applications

  • Driving actuators, solenoids, and other DC-powered devices in distributed control systems

  • High-density modular FLEX I/O networks requiring precise and reliable DC output

FAQ

  • Q: Can the 1794-OB16P handle high-current loads?
    A: Yes, total module output 8 A, individual outputs up to 500 mA

  • Q: Are the outputs fused?
    A: No, external fusing such as SAN-0 MQ4-800mA is recommended

  • Q: Which terminal bases are compatible?
    A: 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more