PRODUCT SKU : 1794-IF2XOF2I

PRODUCT TYPE : Analog Input/Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1794-IF2XOF2I is a FLEX I/O analog combination module that integrates both input and output functionality in a single unit. It features two isolated analog inputs and two isolated analog outputs, supporting both current and voltage signals. With 16-bit resolution and sigma-delta conversion, the module ensures precise signal processing for industrial automation systems. Its compact design and DIN rail mounting make it suitable for distributed control applications requiring reliable analog I/O.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line FLEX I/O 1794

  • Product Type Isolated Analog Input/Output Module

  • Part Number 1794-IF2XOF2I

  • Weight 1.00 lbs (0.45 kg)

  • Inputs 2 isolated analog inputs

    • Current input: 4–20 mA

    • Voltage input: ±10 V

  • Resolution 16-bit

  • Conversion Type Sigma-delta

  • Outputs 2 isolated analog outputs

    • Current output: 4–20 mA

    • Voltage output: ±10 V

  • FlexBus Current 50 mA

  • Thermal Dissipation 11.3 BTU/hr @ 31.2 V DC max

  • Mounting Style DIN rail

  • Enclosure Type Open-style (IP20)

Application Scenarios

  • Distributed control systems requiring both analog input and output in one module

  • Process automation with precise current and voltage signal handling

  • Industrial environments needing isolated I/O for noise immunity and reliability

FAQ

Q: How many channels does the 1794-IF2XOF2I support?  A: It provides 2 isolated inputs and 2 isolated outputs.

Q: What resolution is available for signal conversion?  A: The module offers 16-bit resolution with sigma-delta conversion.

Q: What type of signals can be connected?  A: Both current (4–20 mA) and voltage (±10 V) signals are supported.

Comparable Models

  • 1794-IF2XOF2I: Combination analog I/O with isolated channels (this model)

  • 1794-IF4I: 4-channel isolated analog input module

  • 1794-OF4I: 4-channel isolated analog output module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more