Skip to content

What are you looking for?


You may also like

1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module
1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module
1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module
1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module

1756-OF8I | Allen-Bradley ControlLogix Isolated Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-OF8I

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-OF8I is an isolated 8-point analog output module from the ControlLogix series. It provides precise voltage and current outputs for process and motion control applications. Each channel is individually isolated to ensure reliable signal integrity and reduce electrical interference.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Model / Part Number: 1756-OF8I

  • Product Type: Isolated Analog Output Module

  • Weight: 0.50 lbs (0.23 kg)

  • Number of Outputs: 8 isolated channels (current/voltage)

  • Output Current Range: 0–20 mA, 4–20 mA

  • Output Voltage Range: ±10V, 0–10V, 0–5V

  • Resolution: 15–16 bits

  • Data Format: IEEE 32-bit floating point

  • Conversion Method: R-2R ladder DAC, monotonic with no missing codes

  • Open Circuit Detection: Supported (current mode only)

  • Short Circuit Detection: Supported (voltage mode only)

  • Overvoltage Protection: ±30V DC

  • Isolation Voltage: 50V DC continuous

  • Current Draw (24V DC): 400 mA

  • Power Dissipation: 6.5 W

  • Thermal Dissipation: 22.2 BTU/hr

  • Terminal Blocks Supported: 1756-TBNH, 1756-TBSH, 1756-TBCH, 1756-TBS6H

  • Enclosure Type: Open-style

  • Mounting: Chassis-based

Key Features

  • Eight fully isolated analog output channels for high signal integrity

  • Supports both voltage and current outputs

  • High 16-bit resolution for precise control

  • Built-in protection against open and short circuits

  • ±30V DC overvoltage protection for safety

  • Compatible with multiple removable terminal block options

  • Suitable for demanding process control applications

Application Scenarios

  • Industrial process and motion control systems

  • PID loop control in automation

  • Control of drives, valves, and actuators

  • Precision analog instrumentation

  • Distributed I/O systems in ControlLogix environments

FAQs

  • Q: What output types are supported?

    • A: Voltage (±10V, 0–10V, 0–5V) and current (0–20mA, 4–20mA).

  • Q: Are channels isolated?

    • A: Yes, each of the eight channels is individually isolated.

  • Q: Which terminal blocks can be used?

    • A: Compatible blocks include 1756-TBNH, 1756-TBSH, 1756-TBCH, 1756-TBS6H.

  • Q: How is overvoltage handled?

    • A: The module provides ±30V DC overvoltage protection for both current and voltage outputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more