Skip to content

What are you looking for?


You may also like

1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module
1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module
1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module
1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module

1756-IB16ISOE | Allen-Bradley | ControlLogix | DC Isolated SOE Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IB16ISOE

PRODUCT TYPE : Digital DC Isolated Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1756-IB16ISOE is a ControlLogix digital input module designed for sequence-of-events (SOE) applications. It provides 16 individually isolated DC inputs, enabling precise event capture with high-speed response. The module supports both sink and source configurations, making it versatile for industrial monitoring and control systems.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Part Number: 1756-IB16ISOE

  • Category: PLCs

  • Weight: 0.44 lbs (0.20 kg)

  • Module Type: Digital DC Isolated Input (SOE)

  • Inputs: 16 isolated channels

  • Input Voltage Range: 24–48 V DC (sink/source)

  • Operating Voltage Range: 10–55 V DC

  • Input Delay Time: 50 µs + selectable filter time

  • Minimum Operating Current: 5.5 mA at 55 V DC

  • Maximum Operating Current: 2 mA at 10 V DC

  • Off-State Current (Max): 1.5 mA

  • Power Dissipation: 5.5 W at 60 °C

  • Backplane Current Draw:

    • 275 mA @ 5 V DC

    • 2 mA @ 24 V DC

  • Terminal Blocks: 1756-TBCH, 1756-TBS6H (removable)

  • Isolation Voltage: 75 V continuous; type-tested at 1200 V AC for 2 s

Features

  • High-speed event capture with 50 µs response

  • Individually isolated inputs for improved reliability

  • Supports both sink and source wiring configurations

  • Designed for sequence-of-events monitoring in critical applications

  • Compatible with removable terminal blocks for simplified wiring

Application Scenarios

  • Power System Monitoring: Event capture for fault detection and logging

  • Industrial Automation: Precise input tracking for safety and control systems

  • Critical Infrastructure: Sequence-of-events recording in energy and utility networks

FAQ

  • Q: How many inputs does the 1756-IB16ISOE provide?  A: Sixteen individually isolated DC inputs.

  • Q: What is the input delay time?  A: 50 microseconds plus selectable filter time.

  • Q: Which terminal blocks are compatible?  A: 1756-TBCH and 1756-TBS6H.

  • Q: What isolation voltage is supported?  A: 75 V continuous, tested at 1200 V AC for 2 seconds.

  • Q: How does this compare to the 1756-IB16?  A: The 1756-IB16ISOE provides isolated inputs and SOE functionality, while the 1756-IB16 is a standard DC input module without event sequencing.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more
Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

Site Acceptance Testing (SAT) for PLC Control Systems: An Engineering Execution Guide

The Site Acceptance Test (SAT) represents the definitive handover stage in industrial automation projects. While the Factory Acceptance Test confirms cabinet hardware assembly off-site, the SAT validates real-world performance under live site conditions. Consequently, a structured execution strategy prevents equipment damage and guarantees seamless integration into plant operations.

Read more
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more